Fast scanning and efficient photodetection in a simple two-photon microscope.
نویسندگان
چکیده
Two-photon laser scan microscopy carries many advantages for work on brain slices and bulk tissue. However, it has very low signal levels compared to conventional fluorescence microscopy. This is disadvantageous in fast imaging applications when photon shot noise is limiting. Working on brain slices with excitation powers of 8-10 mW at the specimen plane, the resting signal from cerebellar Purkinje cell somas loaded with 10 microM Oregon Green 488 BAPTA-1 averaged 4 detected photons/micros; axons of interneurons loaded with 200 microM of this indicator yielded about 1 photon/micros. To obtain satisfactory images at high time resolution, long pixel dwell times are required and data collection should be restricted to as few pixels as necessary. Furthermore, a large proportion of total measurement time (duty cycle) should be available for data collection. We therefore developed a method for scanning small regions of interest with line repetition rates two to four times higher than conventional ones and a duty cycle of 70%. We also compared the performance of several photodetectors and found the optimum choice to depend strongly on the photon flux during a given application. For fluxes smaller than 5 photons/micros, the photon counting avalanche photodiode shows the best signal to noise ratio. At larger fluxes, photomultipliers or intensified photodiodes are superior.
منابع مشابه
Fast Scanning Two-Photon Microscopy
Fast scanning two-photon microscopy coupled with the use light activated ion channels provides the basis for fast imaging and stimulation in the characterization of in vivo neural networks. A two-photon microscope capable of fast scanning using acousto-optic deflectors was designed and implemented. The software controller was expanded so that random access scan in three dimensions could be hand...
متن کاملA custom confocal and two-photon digital laser scanning microscope.
We describe a custom one-photon (confocal) and two-photon all-digital (photon counting) laser scanning microscope. The confocal component uses two avalanche photodiodes (APDs) as the fluorescence detector to achieve high sensitivity and to overcome the limited photon counting rate of a single APD ( approximately 5 MHz). The confocal component is approximately nine times more efficient than our ...
متن کاملTwo-Photon Imaging with Diffractive Optical Elements
Two-photon imaging has become a useful tool for optical monitoring of neural circuits, but it requires high laser power and serial scanning of each pixel in a sample. This results in slow imaging rates, limiting the measurements of fast signals such as neuronal activity. To improve the speed and signal-to-noise ratio of two-photon imaging, we introduce a simple modification of a two-photon micr...
متن کاملSLM Microscopy: Scanless Two-Photon Imaging and Photostimulation with Spatial Light Modulators
Laser microscopy has generally poor temporal resolution, caused by the serial scanning of each pixel. This is a significant problem for imaging or optically manipulating neural circuits, since neuronal activity is fast. To help surmount this limitation, we have developed a "scanless" microscope that does not contain mechanically moving parts. This microscope uses a diffractive spatial light mod...
متن کاملEffects of Temperature on Radiative Properties of Nanoscale Multilayer with Coherent Formulation in Visible Wavelengths
During the past two decades, there have been tremendous developments in near-field imaging and local probing techniques. Examples are the Scanning Tunneling Microscope (STM), Atomic Force Microscope (AFM), Near-field Scanning Optical Microscope (NSOM), Photon Scanning Tunneling Microscope (PSTM), and Scanning Thermal Microscope (SThM).Results showed that the average reflectance for a dopant con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neuroscience methods
دوره 92 1-2 شماره
صفحات -
تاریخ انتشار 1999