Integral Plus Resonant Sliding Mode Direct Power Control for VSC-HVDC Systems under Unbalanced Grid Voltage Conditions
نویسندگان
چکیده
An integral plus resonant sliding mode direct power control (IRSMC DPC) strategy for voltage source converter high voltage direct current (VSC-HVDC) systems under unbalanced grid voltage conditions is proposed in this paper. Through detailed instantaneous power flow analysis, a generalized power compensation method, by which the ratio between the amplitude of active and reactive power ripples can be controlled continuously, is obtained. This enables the system to provide flexible power control, so that the desired performance of the system on both the ac and dc sides can be attained under different operating conditions. When the grid voltage is unbalanced, one or both of the active and reactive power terms contain ripples, oscillating at twice the grid frequency, to obtain non-distorted ac current. A power controller consisting of the proportional, integral and resonant control laws is designed using the sliding mode control approach, to achieve accurate power control objective. Simulation studies on a two-terminal VSC-HVDC system using MATLAB/SIMULINK (R2013b, Mathworks, Natick, MA, USA) are conducted to verify the effectiveness of the IRSMC DPC strategy. The results show that this strategy ensures satisfactory performance of the system over a wide range of operating conditions.
منابع مشابه
Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملA novel control method for a VSC-HVDC system in a grid-connected wind farm
The voltage source converter-high voltage direct current (VSC-HVDC) transmission is the ideal integration technology for grid-connected wind farms. A passivity-based control (PBC) method for VSC-HVDC when the wind farm voltage is unbalanced is proposed in this paper. The mathematical model of a VSC with unbalanced voltage is established. The PBC theory including dissipation inequality and syste...
متن کاملRobust Fuzzy-Second Order Sliding Mode based Direct Power Control for Voltage Source Converter
This paper focuses on a second order sliding mode based direct power controller (SOSM-DPC) of a three-phase grid-connected voltage source converter (VSC). The proposed control scheme combined with fuzzy logic aims at regulating the DC-link voltage of the converter and precisely tracking arbitrary power references, in order to easily control the system’s power factor. Therefore measures are prop...
متن کاملSimulation of Vsc Based Hvdc Transmission System for the Integration of Windfarm into Grid
Wind energy has huge potential to become major source of renewable energy for the modern world. For integrating wind farms to the AC grid, HVDC transmission systems have several advantages over AC transmission systems. This paper presents the design and control of voltage source converter based HVDC system for integration of wind farms in to AC grid. The designed VSC-HVDC system performance und...
متن کامل