Parallel two-channel near- and far-field fluorescence microscopy.

نویسندگان

  • Dorinel Verdes
  • Thomas Ruckstuhl
  • Stefan Seeger
چکیده

We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles above the critical angle of the waterglass interface. An aspheric lens, incorporated into the solid parabolic element, is used for diffraction-limited laser focusing and for collecting fluorescence at low angles with respect to the optical axis. By separated collection of the fluorescence emitted into supercritical and subcritical angles, two detection volumes strongly differing in their axial resolution are generated at the surface of a glass cover slip. The collection of supercritical angle fluorescence (SAF) results in a strict surface confinement of the detection volume, whereas collecting below the critical angle allows gathering the fluorescence emitted several microns deep inside the sample. Consequently, the signals from surface-bound and unbound diffusing fluorescent molecules can be obtained simultaneously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraction of near-field fluorescence from composite signals to provide high resolution images of glial cells.

The subdiffraction optical resolution that can be achieved using near-field optical microscopy has the potential to permit new approaches and insights into subcellular function and molecular dynamics. Despite the potential of this technology, it has been difficult to apply to cellular samples. One significant problem is that sample thickness causes the optical information to be comprised of a c...

متن کامل

Simultaneous near-field and far-field fluorescence microscopy of single molecules.

A new microscope objective is presented for the parallel fluorescence detection below and above the critical angle of total internal reflection with single molecule sensitivity. The collection of supercritical angle fluorescence (SAF) leads to a strongly surface confined detection volume whereas the collection of undercritical angle fluorescence (UAF) allows for the observation of deeper axial ...

متن کامل

Performance of Mid-rise Buildings with Tubular Structure Under the Effect of Near Field Earthquakes

The aim objective of this study is to investigate the effects of near-field earthquakes on the response of mid-rise buildings with tubular structure.  For this purpose, a 20-story building with a square plan of six by six bays, all with 6 m span, and story height of 3.70 m is considered.  Axial force of columns, shear lag, and inter-story drift values are used as the main response parameters. N...

متن کامل

Subdiffraction resolution in far-field fluorescence microscopy.

We overcame the resolution limit of scanning far-field fluorescence microscopy by disabling the fluorescence from the outer part of the focal spot. Whereas a near-UV pulse generates a diffraction-limited distribution of excited molecules, a spatially offset pulse quenches the excited molecules from the outer part of the focus through stimulated emission. This results in a subdiffraction-sized e...

متن کامل

Scanning near-field optical microscopy with white-light illumination: nanoscale imaging and spectroscopy of resonant systems

We present the realisation of near-field spectroscopic measurements with fibre-tip-based scanning near-field microscopy. It allows simultaneous acquisition of near-field optical images in a broad spectral range (400 nm to 1000 nm), thus recovering local spectroscopic information. The technique is essential for understanding the resonant interaction of light with nanostructured objects as the fa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 2007