Crestal bone remodeling around implants placed using a short drilling protocol.

نویسندگان

  • Emanuel Bratu
  • Sorin Mihali
  • Lior Shapira
  • Dana Cristina Bratu
  • Hom-Lay Wang
چکیده

PURPOSE The aim of the study was to examine the influence of a short drilling protocol on peri-implant crestal bone levels. MATERIALS AND METHODS Forty implants were placed in the posterior mandibles of 20 patients. The implants (diameter, 4.2 mm; length, 10 to 11.5 mm) were inserted in pairs: one implant was inserted using the standard drilling protocol (five drills in sequence), while the other was inserted using the short drilling protocol sequence (three drills). All implants received healing abutments and were restored with single-unit restorations after 3 months of healing. Analysis of crestal bone level was based on radiographs taken at insertion and at 3, 6, and 12 months after insertion. The results were analyzed using software Image J 1.46r (National Institutes of Health). Crestal bone level was measured in millimeters at the distal aspect of each implant. RESULTS None of the implants in either group was lost during the 12-month follow-up period, and all patients completed the follow-up examination. The drilling time for the insertion of one implant with the short drilling protocol was 1.03 ± 3.63 minutes compared to 1.57 ± 2.88 minutes for the standard protocol. The mean values of crestal bone loss at 12 months were 0.94 ± 0.43 mm for implants placed using the standard protocol and 0.90 ± 0.33 mm for implants placed using the short drilling protocol. No statistically significant differences were noted. CONCLUSION Using the short drilling protocol reduced the surgery time by approximately 50% and did not affect crestal bone remodeling during the first year postinsertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه میزان تحلیل استخوان کرستال اطراف ایمپلنت‌های Replace با دو روش Submerge و Non-submerge

Background and Aim: It is well recognized that implant treatment is common worldwide, but the approach to success is not predictable because of bone loss that occurs around the implants. Also there are many factors affecting crestal bone loss around the implants that one of them is the surgical protocol of implant installation. The purpose of this investigation was to evaluate the amount of cre...

متن کامل

بررسی رادیوگرافیک اثر بارگذاری تدریجی بر روی تغییرات استخوان کرستال و تراکم استخوان اطراف ایمپلنت‌های تک واحدی خلف ماگزیلا

Background and Aim: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single crowns by an accurate longitudinal radiographic assessment technique. Materials and Methods: Eleven Micro-Thread Osseo Speed dental implants were place...

متن کامل

Radiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation

Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...

متن کامل

Peri-implant bone level around implants with platform-switched abutments.

PURPOSE The purpose of this clinical trial was to evaluate whether the crestal bone height around dental implants could be influenced by the use of a platform-switching protocol. MATERIALS AND METHODS All implants placed in the year 2006 in healed bone without any need for ridge augmentation were included in this study. The following groups were created: (1) wide-diameter implants were placed...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2015