Primary transcatheter umbrella closure of perimembranous ventricular septal defect.
نویسندگان
چکیده
OBJECTIVES The starting hypothesis was that some perimembranous ventricular septal defects can be closed safely and effectively with a Bard Rashkind double umbrella introduced through a long transvenous sheath. DESIGN A descriptive study of all patients who underwent attempted transcatheter umbrella closure of a perimembranous ventricular septal defect. Those patients selected for the study had symptoms of a ventricular septal defect and a perimembranous ventricular septal defect shown by transthoracic echocardiography. The morphological criteria used were a posterior perimembranous defect with a diameter of < or = 8 mm not associated with overriding of the aortic or pulmonary valve or with aortic valve prolapse. The haemodynamic criteria for inclusion in the study were a right to left ventricular systolic pressure ratio of > 0.45, a Doppler derived right ventricular systolic pressure of > 50 mm Hg, and a pulmonary to systemic flow ratio > 3:1. SETTING A tertiary referral centre. PATIENTS 13 infants, children, and adolescents with a perimembranous ventricular septal defect aged 3 weeks to 16 years and weighing 1.8-46 kg. INTERVENTIONS A modified Rashkind ductal double umbrella was introduced through a long transvenous sheath and positioned on either side of the ventricular septal defect. Placement was guided by transoesophageal echocardiography. RESULTS 10 out of 13 patients underwent successful partial or complete closure of a perimembranous ventricular septal defect. There were three placement failures. Two of these were associated with a ventricular septal defect too large for the umbrella device. In a third case the umbrella was opened in the left ventricular outflow tract necessitating surgical removal and closure of the ventricular septal defect. CONCLUSION Transcatheter umbrella closure of a perimembranous ventricular septal defect is technically feasible and can be therapeutically successful, although the procedure is moderately difficult to perform and the mean procedure time is > 120 minutes. It is an alternative to surgery in some cases, but the overall results would not support its routine use even with the introduction of larger devices of the current design.
منابع مشابه
Transcatheter closure of iatrogenic perimembranous ventricular septal defect after aortic valve and ascending aorta replacement using an Amplatzer membranous ventricular septal occluder.
Iatrogenic perimembranous ventricular septal defect is a rare complication after surgical replacement of the aortic valve, and so transcatheter closure of such a defect is not a routine procedure. We report the successful closure of an iatrogenic perimembranous ventricular septal defect which occurred after the replacement of the aortic valve and ascending aorta.
متن کاملTranscatheter closure of perimembranous ventricular septal defects with Amplatzer occluder assessed by real-time three-dimensional echocardiography.
We report our initial experience in two patients using real-time three-dimensional echocardiography to assess perimembranous ventricular septal defect and device morphology and their relation with contiguous cardiac structure. Defect size and rims as well as device position and profile were displayed from the three-dimensional "en face" views. We think that real-time three-dimensional echocardi...
متن کاملSimultaneous Transcatheter Closure of Ventricular Septal Defect and Pulmonary Valvuloplasty
BACKGROUND Transcatheter balloon valvuloplasty has been the accepted first line treatment for congenital pulmonic stenosis (PS) in children. Transcatheter closure of perimembranous ventricular septal defect (VSD) with Amplatzer VSD occluder is an alternative to surgical repair. CASE PRESENTATION A 12 year old boy presented with history of exertional dyspnea and atypical chest pain. Physical f...
متن کاملTranscatheter closure of multi-hole perimembranous ventricular septal defect with aneurysm using two occluders
Corresponding author: Sheng-hua Zhou MD, PhD, Department of Cardiology, Second Xiangya Hospital, Central South University, 139 Middle Renmin Road, Changsha, Hunan 410011, China, phone: +86 731 85292012, fax: +86 731 85294038, e-mail: [email protected] Received: 28.08.2016, accepted: 10.11.2016. Transcatheter closure of multi-hole perimembranous ventricular septal defect with aneurysm usi...
متن کاملSurgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 72 4 شماره
صفحات -
تاریخ انتشار 1994