Simulation Sickness Comparison between a Limited Field of View Virtual Reality Head Mounted Display (oculus) and a Medium Range Field of View Static Ecological Driving Simulator (eco2)

نویسندگان

  • Baris Aykent
  • Zhao Yang
  • Frédéric Merienne
چکیده

In this article, an experimental procedure is presented in order to evaluate the role of having HMD oculus and (Eco2 driving simulator) in terms of driving simulation sickness. The driving simulation sickness is investigated with respect to SSQ (simulator sickness questionnaire) and vestibular dynamics (head movements) of the driver participants for a specific driving scenario. The scenario of driving task is created by using open source “iiVR (institut image virtual reality)” software which is developed by Institut Image Arts et Métiers ParisTech. The experiments are executed in static mode for the driving simulators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Evaluation of a Virtual Reality Driving Simulator

This work presents the design and set-up of a virtual reality driving simulator for development and evaluation of future automotive HMI concepts. The Oculus Rift based virtual reality driving simulation described in this work is an immersive 3D virtual reality simulator, which gives the driver a near-realistic driving experience. Oculus Rift is a low-latency 360° head tracking virtual reality h...

متن کامل

Head-Mounted Displays for HCI Validations While Driving

To provide reliable and valid findings when evaluating innovative in-car devices in the automotive context highly realistic driving environments are recommended. Nowadays, in-car devices are mostly evaluated due to driving simulator studies followed by real car driving experiments. Driving simulators are characterized by high internal validity, but weak regarding ecological validity. Real car d...

متن کامل

Limited Field of View of Head-Mounted Displays Is Not the Cause of Distance Underestimation in Virtual Environments

Observers binocularly viewed a target placed in a large open field under two viewing conditions: unrestricted field of view and reduced field of view, as effected using a simulated head-mounted display. Observers indicated the perceived distance of the target, which ranged from 2 to 15 m, using both verbal report and blind walking. For neither response was there a reliable effect of limiting th...

متن کامل

Simulator Sickness Research Summary

Simulator Sickness (SS) is a form of Motion Sickness (MS) that does not require true motion – but does require a wide field of view (FOV) visual display [5, 46, 64]. Like all varieties of MS, an intact vestibular system is necessary to experience SS [12]. It has been called visually induced motion sickness [3, 52, 48] and Cinerama sickness [3, 5, 52]. The term “vection” is used to describe a vi...

متن کامل

Vection and cybersickness generated by head-and-display motion in the Oculus Rift

Cybersickness is often experienced when viewing virtual environments through head-mounted displays (HMDs). This study examined whether vection (i.e., illusory self-motion) and mismatches between perceived and physical head motions contribute to such adverse experiences. Observers made oscillatory yaw head rotations while viewing stereoscopic optic flow through an Oculus Rift HMD. Vection and cy...

متن کامل

ذخیره در منابع من