Time Course of Current of Injury Is Related to Acute Stability of Active-Fixation Pacing Leads in Rabbits
نویسندگان
چکیده
BACKGROUND Magnitude of current of injury (COI) consequent to pacemaker lead fixation is recognized as a predictor of acute lead stability. It is unclear whether dynamic monitoring of COI after lead fixation provides additional information beyond a single assessment performed at the time of fixation. OBJECTIVES This study was aimed to test the hypothesis that the time course of COI is related to acute lead stability. METHODS AND RESULTS Active fixation leads with fixed screw were anchored to either Langendorff-perfused rabbit hearts endocardially or in vivo hearts epicardially in manners of contact the helix with no rotation, half rotation and full rotation, respectively. Intracardiac electrogram (EGM) was monitored dynamically from onset to resolution of COI, and magnitudes of intrinsic R wave and COI, including ST-segment elevation, ST/R and intracardiac EGM duration (IED), were measured. A digital force gauge was applied to assess lead stability. In vitro, COI in contacted leads was significantly smaller than those in half rotated (p<0.05) and fully rotated leads (p<0.05), and presented most precipitous recovery to baseline (1.5±1.1 min, p<0.05). Half-rotated and fully rotated leads manifested the same magnitude of COI right after placement. However, the time course of COI was significantly longer in fully rotated leads than that in half rotated leads (26.5±2.8 min vs. 5.6±2.0 min, p<0.05). Similar findings were observed in vivo. The time course of COI was significantly correlated with the force needed to detach the lead from myocardium (r = 0. 72, n = 48, p<0.001). CONCLUSIONS Time course of COI is related to acute lead stability in rabbits. One might be misled by a single assessment of COI magnitude right after lead placement, whereas persistence of COI is likely to be a useful indicator of adequate lead stability.
منابع مشابه
Retracted: Time course changes of oxidative stress and inflammation in hyperoxia-induced acute lung injury in rats
متن کامل
Time course changes of oxidative stress and inflammation in hyperoxia-induced acute lung injury in rats
Objective(s):Therapies with high levels of oxygen are commonly used in the management of critical care. However, prolonged exposure to hyperoxia can cause acute lung injury. Although oxidative stress and inflammation are purported to play an important role in the pathogenesis of acute lung injury, the exact mechanisms are still less known in the hyperoxic acute lung injury (HALI). Materials ...
متن کاملDouble-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation
Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the ...
متن کاملMorphology Of Current Of Injury Does Not Predict Long Term Active Fixation ICD Lead Performance
BACKGROUND Currents of injury (COI) have been associated with improved lead performance during perioperative measurements in pacemaker and ICD implants. Their relevance on long term lead stability remains unclear. METHODS Unipolar signals were recorded immediately after active fixation ICD lead positioning, blinded to the implanting surgeon. Signals were assigned to prespecified COI types by ...
متن کاملLong-term reliability of sweet-tip type screw-in leads
BACKGROUND Active fixation leads have provided stable atrial and ventricular pacing; however, long-term follow-up data have not been satisfactory. The purpose of this study was to investigate the long-term reliability of active fixation leads and their electrical characteristic stability. METHODS A total of 1196 pacing leads were implanted in 830 patients consecutively between 2002 and 2013. ...
متن کامل