Transapical aortic valve implantation in patients with pre-existing mitral valve prostheses: a case report
نویسندگان
چکیده
BACKGROUND Transcatheter aortic valve implantation (TAVI) has proven to be a valid option for patients with severe aortic stenosis who are at high perioperative risk, particularly in patients with previous cardiac surgery. Several patients with previous mitral valve surgery were reported to have been successfully treated with TAVI. CASE PRESENTATION Two patients, one with mechanical and one with biological mitral valve prosthesis, presented with symptomatic severe aortic stenosis. After discussion among our multidisciplinary heart team transapical approach and a JenaValve™ prosthesis was used for TAVI. Main reasons were to decrease the perioperative risk, avoid a re-opening of the chest via median sternotomy, and discuss the possible superiority of the JenaValve™ device due to its design. The patients were successfully treated and discharged on the 11th and 14th post-operative day, respectively. Echocardiographic follow up before discharge and up to 2.8 years post-operatively showed excellent results. CONCLUSIONS In conclusion, TAVI in patients with preexisting mitral prostheses-mechanical or biological-is feasible, safe, and effective and offers a valid alternative to conventional aortic valve replacement in this particular re-operation scenario. The JenaValve™ device does not interact with the mitral prosthesis and offers therefore due to its unique design a potential advantage.
منابع مشابه
Transapical aortic valve implantation in the presence of a mitral prosthesis.
Transcatheter aortic valve implantation (TAVI), using the Edwards Sapien balloon expandable valve (Edwards Lifesciences, Irvine, California, USA) has expanded our ability to treat patients with symptomatic severe aortic stenosis, and become the treatment of the choice in high risk inoperable patients (1,2). Further inroads into its application in subgroup populations, such as patients with a fu...
متن کاملEmergency transapical mitral valve-in-valve implantation for bioprosthesis failure: transapical implantation of an Edwards Sapien-XT in a dysfunctional mitral bioprosthesis in a critical patient
Background: Valve-in-Valve (VIV) Transcatheter Aortic Valve Replacement (TAVR) is now the treatment of choice in high-surgical-risk patients with failing aortic bioprosthesis. Although less performed, VIV-Transcatheter Mitral Valve Replacement (TMVR) is a valid treatment option for selected high-risk patients with degenerated mitral bioprostheses. Several cases of elective ViVTAVR and -TMVR hav...
متن کاملSuccessful transapical aortic valve replacement in a patient with a previous mechanical mitral valve replacement.
In this case we illustrate our experience with transapical minimal invasive aortic valve replacement in a patient who previously underwent mitral valve replacement. The implantation did not interfere with the existing prosthesis and could even be used as a further landmark, helping height positioning of the aortic valve.
متن کاملConcomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.
Transcatheter valve implantation is a novel interventional technique, which was developed as an alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation ...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کامل