A new device that allows synchronous intermittent inspiratory chest tube occlusion with any mechanical ventilator.
نویسندگان
چکیده
Controlling a massively leaking bronchopleural fistula (BPF) can prove difficult. In combination with acute respiratory failure (ARF), BPF results in a mortality of 81 percent. Intermittent inspiratory chest tube occlusion (IICTO) is recognized as effective in controlling even the largest BPF; however, IICTO, as previously described, is difficult to use for a variety of reasons. We report two cases of BPF in association with ARF managed with a simple new device that allows the application of IICTO with virtually any mechanical ventilator. The effectiveness of the device and associated technique in controlling BPF leaks is clearly demonstrated and may have played a role in the eventual recovery of a patient with BPF. Further study of the technique is warranted.
منابع مشابه
Work of breathing and airway occlusion pressure during assist-mode mechanical ventilation.
We determined the effect of varying ventilator tidal volume (VT) and inspiratory flow (V) on the inspiratory muscle work (WI) during assist-mode mechanical ventilation (AMV) in four healthy subjects. In another four subjects, under constant chemoreceptor input, we determined the responses of neuromuscular output as assessed by the mouth occlusion pressure (P0.1) to alteration in WI. During AMV,...
متن کاملA technique of pulmonary ventilation with a nasotracheal tube.
A modified naso-endotracheal tube is described which facilitates prolonged intermittent positive pressure ventilation of the lungs in infants and children. A crosspiece allows connection widi the inspiratory and expiratory tubes of a drcle-type mechanical ventilator. The technique of intubation and of securing ths nasal tube to the patient is described in detaiL The tube has been used in 126 pa...
متن کاملDemand and continuous flow intermittent mandatory ventilation systems.
A mechanical lung was used to evaluate the pressure and flow characteristics of four demand and two continuous flow intermittent mandatory ventilation (IMV) systems. The amount of negative pressure required to initiate inspiratory flow and peak expiratory resistance were measured. The inspiratory pressure required to initiate flow in the demand mode was also compared to pressures generated in t...
متن کاملEffect of intermittent subglottic secretion drainage on ventilator-associated pneumonia: A clinical trial
BACKGROUND Secretions contaminated with oral, nasal, and gastric bacteria accumulate in the subglottic space, above the endotracheal tube cuff. If these secretions are aspirated into lower airways, the intubated patient will be susceptible to ventilator-associated pneumonia (VAP). The aim of this study was to investigate the effect of inspiratory pause maneuver for intermittent subglottic secre...
متن کاملAdjustable inspiratory occlusion valve in experimental bronchopleural fistula. A new therapeutic perspective.
PURPOSE To assess the efficacy of an adjustable inspiratory occlusion valve in experimental bronchopleural fistula during mechanical ventilation. METHODS We studied six mechanically ventilated pigs in a surgically created, reproducible model of bronchopleural fistula managed with mechanical ventilation and water-sealed thoracic drainage. An adjustable inspiratory occlusion valve was placed be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 97 6 شماره
صفحات -
تاریخ انتشار 1990