Cubic control for phase I smart base-isolated benchmark building with emphasis on nonstructural performance
نویسندگان
چکیده
Most control techniques in the structural engineering literature are aimed at improving performance of the primary structural system, but may have limited or even adverse effect on nonstructural components during strong seismic events. In this paper, we emphasize nonstructural performance using an active controller with a cubic nonlinearity. The controller is optimized based on the frequency response functions of a SDOF nonlinear oscillator. An eight-storey base-isolated benchmark building recently proposed by the ASCE structural control committee is studied as a demonstration by considering both structural and nonstructural performance indices. We compare the performance of the proposed cubic controller with that of a LQG-based semiactive control system and a passive energy dissipation system. It is shown from the simulation results that in most benchmark test cases, the cubic control system produces better nonstructural performance while maintaining good response characteristics of the primary structural system. Further research directions for this cubic control system are also pointed out. Copyright # 2005 John Wiley & Sons, Ltd.
منابع مشابه
A Novel Nonlinear Control System with Emphasis on Nonstructural Performance (2003-2004)
Most control techniques in the structural engineering literature are aimed at improving performance of the primary structural part, but they may have limited or reverse effect on the nonstructural component during strong seismic events. In this paper, we emphasize the nonstructural performance using a cubic nonlinear active control system optimized in the frequency response functions of an SDOF...
متن کاملStructural control benchmark problem: Phase II—Nonlinear smart base-isolated building subjected to near-fault earthquakes
Many branches of engineering, mathematics, and sciences, have relied on benchmark problems as a standard means to compare different solution techniques. Since 1996, the ASCE Structural Control and Monitoring Committee and Task Group on Benchmark Problems, the U.S. Panel on structural control, and IASCM have developed a series of benchmark control problems that offer a set of carefully modeled r...
متن کاملSmart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems
Sample controllers for a three-dimensional smart base-isolated building benchmark problem with linear and frictional isolation system are presented in this paper. A Kalman filter is used to estimate the states based on absolute acceleration measurements. Input filters are used to better inform the controller of the spectral content of the earthquake excitations. A reduced order control-oriented...
متن کاملSmart base-isolated benchmark building part IV: Phase II sample controllers for nonlinear isolation systems
The first phase of the seismically excited base-isolated benchmark building was received well by the structural control community, culminating in the March 2006 journal special issue. The special issue contained contributions from over dozen participants world-wide. While the focus of the Phase I effort was on linear isolation systems, Phase II attempts to galvanize research efforts on control ...
متن کاملSemiactive control strategy for a phase II smart base isolated benchmark building
This paper presents a semiactive control strategy for the seismic protection of the phase II smart base isolated benchmark building subjected to near-fault earthquakes. Magnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated buil...
متن کامل