AutoSet nasal CPAP titration: constancy of pressure, compliance and effectiveness at 8 month follow-up.
نویسندگان
چکیده
We have previously shown that AutoSet satisfactorily improves sleep-disordered breathing and sleep architecture in subjects with obstructive sleep apnoea (OSA) syndrome. The aim of this study was to determine, in subjects treated with long-term conventional fixed pressure continuous positive airway pressure (CPAP) at the AutoSet recommended pressure, whether: the long-term compliance is satisfactory; the improvement persists once initial rebound is over; the titration pressure is stable with time; and the titration pressure is comparable with manual titration pressure using a similar end-point. Twenty males with OSA, previously studied with full polysomnography on their diagnostic night, at manual and AutoSet titration, and at the AutoSet recommended fixed pressure, were re-studied after a mean of 3 and 8 months of treatment at the recommended fixed pressure. Re-study included home respiratory monitoring (Nellcor EdenTrace), and repeated manual and AutoSet titration with polysomnography. Compliance was assessed with hour-meter readings. Mean (+/-SEM) usage was 5.7 +/- 0.1 h.night-1 at 3 and 8 months. The arousal index remained normalized. Diagnostic respiratory disturbance index (RDI) was 60.3 +/- 5.7 events.h-1. On AutoSet at fixed CPAP, RDI was initially 2.6 +/- 0.7 events.h-1, then rose slightly (p < 0.001) to 4.3 +/- 0.6 events.h-1 at 3 months, and was 3.6 +/- 0.5 events.h-1 at 8 months. AutoSet titration pressure was: 9.9 +/- 0.4 cmH2O initially, 10.6 +/- 0.4 cmH2O at 3 months, and 9.7 +/- 0.5 cmH2O at 8 months (NS). Manual titration pressure at 8 months was 10.4 +/- 0.4 cmH2O. The standard deviation of the discrepancy with AutoSet was 0.84 cmH2O. In conclusion, the AutoSet recommended pressure varies little with time, and closely predicts the final manual titration pressure; the improvement in respiratory disturbance index was largely maintained, and compliance was good, although probably enhanced by close supervision.
منابع مشابه
Pre-eclampsia and nasal CPAP: part 2. Hypertension during pregnancy, chronic snoring, and early nasal CPAP intervention.
OBJECTIVES To evaluate the potential benefit of nasal continuous positive airway pressure (CPAP) administration in pregnant women recognized to have hypertension early in pregnancy. METHODS This is a randomized study comparing the addition of nasal CPAP treatment to standard prenatal care to standard prenatal care alone in hypertensive women treated with alpha-methyl dopa during early pregnan...
متن کاملObjective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.
Compliance with nasal continuous positive airway pressure (CPAP) has become a major concern, since this treatment is efficacious, but constraining. In 46 consecutive obstructive sleep apnoea (OSA) patients, we measured compliance with nasal CPAP by establishing a mean rate of use, with a built-in time counter read at three-month intervals, over a mean follow-up period of 232 +/- 27 days. The me...
متن کاملIntelligent CPAP systems: clinical experience.
Nasal continuous positive airway pressure (CPAP) remains the treatment of choice for obstructive sleep apnoea (OSA) syndrome. It is believed to work by pneumatically splinting the upper airway. 2 As the pressure is gradually increased the subject passes through a spectrum of gradually decreasing severity of obstruction. 4 Frankobstructiveapnoeas,hypopnoeas, and desaturation first disappear, the...
متن کاملTherapy with nCPAP: incomplete elimination of Sleep Related Breathing Disorder.
Correct assessment of the overall treatment effectiveness requires knowledge about therapy compliance and efficacy. This study aimed to determine overall long-term apnoea alleviation after continuous positive airway pressure (CPAP) in a complete sleep laboratory cohort. Out of 209 consecutive CPAP candidates (mean age 57+/-12 yrs, body mass index (BMI) 30.0+/-5.1 kg x m2, respiratory disturbanc...
متن کاملReliability of home CPAP titration with different automatic CPAP devices
BACKGROUND CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420). METHODS Sixteen untreated obstructive sleep apnea pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 10 9 شماره
صفحات -
تاریخ انتشار 1997