Cold Chopper System for Mid-infrared Instruments
نویسندگان
چکیده
We have developed a cold chopper system for mid-infrared observations. This system is installed into the newly developing mid-infrared instrument, MAX38, for the University of Tokyo Atacama 1.0-m telescope. It is cooled to about 9K. The cold chopper mirror is controlled by a piezoelectric actuator with a flexure hinge lever, and enables square-wave chopping at a frequency up to 7.8 Hz. At the moment, the maximum throw of the chopper is 30 arcseconds on the sky. This cooled chopping mirror system can also be applied to the tip-tilt mirror for SPICA infrared space telescope. We carried out the first light with Kanata 1.5-m telescope at Higashi-Hiroshima Observatory (Hiroshima, Japan) in June 2007 and March 2008. In this observation, we demonstrated that the cold chopper could cancel out the atmospheric turbulence noise of a frequency of 5 Hz at 8.9 micron.
منابع مشابه
Frequency comb assisted mid-infrared spectroscopy of cold molecular ions.
A mid-infrared spectrometer consisting of a high power optical parametric oscillator, a frequency comb, and a cold ion trap is described and characterized. The idler frequency at 3 μm is measured accurately by analyzing the pump and signal beat frequencies with the comb. This is done via two spectrum analyzers, allowing for a wide and continuous scanning ideal for spectroscopy of cold molecules...
متن کاملThe new cold neutron chopper spectrometer at the Spallation Neutron Source: design and performance.
The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at ...
متن کاملNote: significant increase to the temporal resolution of 2D X-ray detectors using a novel beam chopper system.
The investigation of short time dynamics using X-ray scattering techniques is commonly limited either by the read out frequency of the detector or by a low intensity. In this paper, we present a chopper system, which can increase the temporal resolution of 2D X-ray detectors by a factor of 13. This technique only applies to amorphous or polycrystalline samples due to their circular diffraction ...
متن کاملMid-infrared guided optics: a perspective for astronomical instruments.
Research activities during the last decade have shown the strong potential of photonic devices to greatly simplify ground based and space borne astronomical instruments and to improve their performance. We focus specifically on the mid-infrared wavelength regime (about 5-20 microm), a spectral range offering access to warm objects (about 300 K) and to spectral features that can be interpreted a...
متن کاملFourier transform infrared spectroscopy approach for measurements of photoluminescence and electroluminescence in mid-infrared.
An improved Fourier transform infrared spectroscopy approach adapting to photoluminescence and electroluminescence measurements in mid-infrared has been developed, in which diode-pumped solid-state excitation lasers were adopted for photoluminescence excitation. In this approach, three different Fourier transform infrared modes of rapid scan, double modulation, and step scan were software switc...
متن کامل