Ciba Corning ACS:180 testosterone assay evaluated.
نویسندگان
چکیده
A fully automated direct assay of testosterone has been developed for the Ciba Corning ACS:180 immunoassay system. We have evaluated this method and compared specimen results with those from the Diagnostic Products Corp. (DPC) and Medgenix direct assays and an in-house extraction assay. Accuracy of the method was assessed by measuring GC-MS-targeted serum pools. Within-assay im- precision was <6% and between-assay imprecision <9% over the concentration range examined. High concentrations of lipid caused an increase in the measured testosterone but other potential interferents were without effect. Recovery was quantitative but was affected by sex-hormone-binding globulin. The method was positively biased with respect to the DPC and Medgenix assays but negatively biased with the extraction assay. Measurement of the GC-MS-targeted serum pools showed the assay to overestimate recovery by approximately 13%. The ACS:180 assay is particularly attractive as a routine assay because it is fully automated, obtains the first result in only 15 min, and shows good assay performance.
منابع مشابه
Serum total testosterone: immunoassay compared with negative chemical ionization gas chromatography-mass spectrometry.
We have developed an electron capture negative chemical ionization gas chromatography-mass spectrometry (GC-MS) procedure to quantify serum testosterone in the clinically relevant range 0.69-69.3 nmol/L and used this procedure to assess Ciba Corning Diagnostics ACS:180 testosterone immunoassay. The GC-MS method involves liquid-liquid extraction of serum samples and synthesis of a pentafluoroben...
متن کاملThe Ciba Corning ACS:180 benchtop immunoassay analyzer.
We describe a new clinical laboratory instrument, the ACS:180, used to automate heterogeneous immunoassay testing. The ACS:180 automates immunoassays in which paramagnetic particles are the solid phase and changes in chemiluminescence are measured. The system can accommodate both competitive and sandwich-type assay configurations. The microprocessor-based instrument fully automates each step of...
متن کاملChemiluminescence receptor assay for measuring vitamin B12 in serum evaluated.
We evaluated a chemiluminescence receptor assay for vitamin B12 in serum (Magic Lite; Ciba Corning Diagnostics), in which an acridinium ester label is used with magnetic particle separation. Within- and between-batch precisions were generally acceptable, except at low analyte concentrations. The reference range determined from 104 elective preoperative patients was 120-610 pmol/L, compared with...
متن کاملVariance function as basis for assessment of test performance: methodological studies with two assays of prostate-specific antigen.
We evaluated the usefulness of a recently described procedure to assess the analytical performance of an assay. To demonstrate the advantages of this approach, we compared the performance of two analytical systems for determining prostate-specific antigen (PSA). Triplicate measurements of PSA with the IMx (Abbott) and the ACS 180 (Ciba Corning) were used to calculate the variance function. This...
متن کاملA prostate-specific antigen-like protein associated with renal cell carcinoma in women.
Renal cell carcinoma (RCC) is the most common form of cancer affecting the kidney. There is currently no biochemical marker for this disease. We have shown that serum-immunoreactive prostate-specific antigen (PSA) levels, as measured by the two-site Ciba-Corning ACS:180 immunochemiluminometric assay, are elevated in women with RCC. Although the levels were low (0.13-0.89 microgram/l), serum PSA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 9 شماره
صفحات -
تاریخ انتشار 1996