A Combined Experimental and Theoretical Study on the Immunoassay of Human Immunoglobulin Using a Quartz Crystal Microbalance

نویسندگان

  • Po-Jen Liao
  • Jeng-Shian Chang
  • Sheng D. Chao
  • Hung-Chi Chang
  • Kuan-Rong Huang
  • Kuang-Chong Wu
  • Tzong-Shyan Wung
چکیده

We investigate a immunoassay biosensor that employs a Quartz Crystal Microbalance (QCM) to detect the specific binding reaction of the (Human IgG1)-(Anti-Human IgG1) protein pair under physiological conditions. In addition to experiments, a three dimensional time domain finite element method (FEM) was used to perform simulations for the biomolecular binding reaction in microfluidic channels. In particular, we discuss the unsteady convective diffusion in the transportation tube, which conveys the buffer solution containing the analyte molecules into the micro-channel where the QCM sensor lies. It is found that the distribution of the analyte concentration in the tube is strongly affected by the flow field, yielding large discrepancies between the simulations and experimental results. Our analysis shows that the conventional assumption of the analyte concentration in the inlet of the micro-channel being uniform and constant in time is inadequate. In addition, we also show that the commonly used procedure in kinetic analysis for estimating binding rate constants from the experimental data would underestimate these rate constants due to neglected diffusion processes from the inlet to the reaction surface. A calibration procedure is proposed to supplement the basic kinetic analysis, thus yielding better consistency with experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atomic Force Microscopy and Quartz Crystal Microbalance Study of the Lectin–Carbohydrate Interaction Kinetics

Two analytical methods, atomic force microscopy and quartz crystal microbalance, were applied to the study of the reaction kinetics occurring between concanavalin A and carboxypeptidase Y, presenting the specific lectin–carbohydrate recognition. The dissociation rate constants for concanavalin A–carboxypeptidase Y complex obtained using both atomic force microscopy and quartz crystal microbalan...

متن کامل

A simultaneous electrochemical impedance and quartz crystal microbalance study on antihuman immunoglobulin G adsorption and human immunoglobulin G reaction.

The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric ...

متن کامل

Human immunoglobulin adsorption investigated by means of quartz crystal microbalance dissipation, atomic force microscopy, surface acoustic wave, and surface plasmon resonance techniques.

Time-resolved adsorption behavior of a human immunoglobin G (hIgG) protein on a hydrophobized gold surface is investigated using multitechniques: quartz crystal microbalance/dissipation (QCM-D) technique; combined surface plasmon resonance (SPR) and Love mode surface acoustic wave (SAW) technique; combined QCM-D and atomic force microscopy (AFM) technique. The adsorbed hIgG forms interfacial st...

متن کامل

Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors.

Quartz crystal microbalance (QCM) immunosensors are based on the principle that adsorption of substances on the surface of a quartz crystal changes its resonance oscillation frequency. A QCM immunosensor was developed for the detection of both cymbidium mosaic potexvirus (CymMV) and odontoglossum ringspot tobamovirus (ORSV) by pre-coating the QCMs with virus-specific antibodies. Upon binding of...

متن کامل

Response of Quartz Crystal Microbalance Loaded with Single-drop Liquid in Gas Phase

The frequency response of quartz crystal microbalance loaded by single-drop liquid is studied in this paper. Previous studies have shown that the relationship between resonant frequency and properties of liquid by completely immersing one side of the crystal in liquid. In this work, only localized portion of crystal was wetted by liquid droplet. Repeated experiment shows the relationship betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010