Pacemaker-ICD/Drug Interaction

نویسنده

  • Tsu-Juey Wu
چکیده

When a drug is prescribed for a patient with a permanent pacemaker or an implantable cardioverter defibrillator (ICD), consideration must be given to the potential interactions. Drug effect on pacemaker performance is usually thought to cause an increase or decrease in pacing threshold. From a practical view, Class IC drugs must be used cautiously in pacemaker patients, especially in those who are pacemaker-dependent. The possibility of a rise in threshold should always be considered in these patients, and the pacemaker output should be programmed to allow an adequate pacing margin of safety. In such patients, automatic output regulation would be particularly useful. Two-third of ICD recipients are treated with antiarrhythmic drugs to reduce the frequency of ventricular tachycardia/ventricular fibrillation (VT/VF) recurrences and enhance quality of life. However, antiarrhythmic drugs may alter ventricular defibrillation threshold (DFT). Class I agents that work primarily by slowing ventricular conduction velocity increase DFT. Class III agents that work primarily by prolonging ventricular action potential duration decrease DFT. Antiarrhythmic drugs with a balance of class I and class III actions (such as amiodarone) may increase or decrease DFT. Besides affecting DFT, antiarrhythmic drugs may also alter arrhythmia cycle length and frequency, pacing thresholds, and post-shock excitability. Finally, interactions between the ICD and the pacemaker may result in sensing problems, leading to multiple counting and inappropriate shocks, VF nondetection, sensing or capture failure post defibrillation, and pacemaker reprogramming induced by defibrillator discharge.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients.

In April 2005, the US Food and Drug Administration (FDA) commented on the current research regarding the use of magnetic resonance imaging (MRI) on patients with a pacemaker or implantable cardioverter-defibrillator (ICD).1 Pacemaker and ICD labeling currently cautions physicians against the use of MRI, and MRI manufacturers contraindicate MRI for pacemaker and ICD patients. As discussed in our...

متن کامل

Adverse Interactions between ICD and Permanent Pacemaker Systems

After the introduction of the implantable cardioverter defibrillator (ICD) in clinical practice by Mirowski in 1980 [Mirowski et al., 1980] the first available devices offered only a basic ventricular pacing option. Since approximately 5-20% of patients with an indication for ICD therapy following implantation criteria at that time (secondary prevention) needed antibradycardia pacing as well, t...

متن کامل

Managing cross talk between a subcutaneous implantable cardioverter-defibrillator and a dual-chamber unipolar pacemaker system

Introduction In cases of patients who have contraindications to transvenous pacing leads but still require pacing, surgically placed epicardial pacing leads are often used. If such a patient warranted implantable cardioverter-defibrillator (ICD), a subcutaneous ICD (S-ICD) system would be ideal from the standpoint of avoidance of transvenous leads, but devicedevice interaction with the epicardi...

متن کامل

Pacemaker and ICD generator reliability: meta-analysis of device registries.

CONTEXT Despite there being millions of pacemaker and implantable cardioverter-defibrillator (ICD) generator implants worldwide, little is known about device reliability. OBJECTIVES To perform a meta-analysis of prospective pacemaker and ICD registries to determine annual rates of pacemaker and ICD malfunction and to identify trends in these rates. DATA SOURCES MEDLINE (January 1966 to Apri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005