Anterior maxilla alveolar ridge dimension and morphology measurement by cone beam computerized tomography (CBCT) for immediate implant treatment planning
نویسندگان
چکیده
BACKGROUND Implants have been widely used to restore missing teeth. Limited information on applied anatomy at the anterior maxilla compromises the clinical outcome for implant placement in this region. In the current study, Cone Beam Computerized Tomography (CBCT) was used to measure alveolar ridge and buccal undercut dimension at the anterior maxilla to help develop treatment planning for immediate implant placement. METHODS CBCT scans were screened to include 51 subjects with full dentition at right maxilla. Measurements were taken at the cross sectional views in the middle of the maxillary right central incisor, lateral incisor, and canine regions. Alveolar height was measured from the alveolar crest to floor of nasal fossa. Alveolar width was measured from the buccal to palatal cortical plate at the coronal, middle, and apical third of the distance from the alveolar crest to floor of the nasal fossa. Buccal undercut location was measured from where the buccal cortical plate started dipping to a line extending at the alveolar crest that was perpendicular to the long axis of the alveolar ridge. The buccal undercut depth was measured from the deepest point of the undercut at the buccal plate to a line tangent to the buccal plate paralleling the long axis of ridge. RESULTS Alveolar width increased from coronal to apical direction for each tooth. Mean alveolar widths (mm) were: central incisor, 9.55; lateral incisor, 8.30; canine, 9.62. The lateral incisor had a significantly smaller alveolar width than the other anterior teeth. No significant difference in ridge height was noted among the teeth. Undercut locations from the alveolar crest (mm) were: central incisor, 5.84; lateral incisor, 3.59; canine, 5.11. Undercut depths (mm) were: central incisor, 0.76; lateral incisor, 0.87; canine, 0.73. The percentages of teeth with buccal undercuts were: central incisor, 41%, lateral incisor, 77%, and canine 33%. Male demonstrate significant larger ridge width compared with females for all three teeth. CONCLUSIONS At anterior maxilla, the lateral incisor has the thinnest alveolar bone, and most frequently exhibits a buccal undercut which is the closest to alveolar ridge compared with other maxillary anterior teeth.
منابع مشابه
Role of Cone Beam Computed Tomography in Rehabilitation of a Traumatised Deficient Maxillary Alveolar Ridge Using Symphyseal Block Graft Placement
Deficiencies in the alveolar ridges cause multiple problems in achieving aesthetic and functional outcome of implant therapy and are commonly restored by using onlay graft from intraoral source. Careful assessment of the recipient as well as the donor site using cone beam computed tomography (CBCT) is a prerequisite to ideal treatment planning. This paper highlights the critical role of CBCT in...
متن کاملApplications of Cone Beam Computed Tomography (CBCT) in Implant Treatment Planning
The objective of this article is to review the literature which describes the evolving role of cone-beam computed tomography in dental implant treatment planning. The literature supports the use of CBCT in dental implant treatment planning particularly in regards to linear measurements, three-dimensional evaluation of alveolar ridge topography, proximity to vital anatomical structures, and fabr...
متن کاملThe Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible
Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...
متن کاملMeasuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique
Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...
متن کاملAnatomic Situation of Posterior Superior Alveolar Artery in Cone-Beam Computed Tomography Images in Maxillary Molar Region
Introduction: Bleeding is an important complication during implant placement. The aim of this study was to evaluate the anatomic situation of the posterior superior alveolar artery (PSAA) in cone-beam computed tomography (CBCT) images in maxillary molar region in an Iranian population. Methods: In this descriptive cross-sectional study, CBCT scans of the edentulous regions of the posterior max...
متن کامل