Starter sequence for steady-state free precession imaging.
نویسنده
چکیده
The dynamic equilibrium exploited by balanced steady-state free precession imaging develops slowly because its formation is dependent on both spin-spin and spin-lattice relaxation times. Attempting to image before steady state is established results in artifacts due to transient signal oscillations. Using a starter sequence to precondition the spin system can significantly reduce the delay before imaging. An improved design for a steady-state starter sequence is presented. The new sequence has the advantage of uniformly exciting the steady-state response for all resonance offsets and can be phase cycled to suppress banding artifacts.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملSpectrally selective imaging with wideband balanced steady-state free precession MRI.
PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...
متن کاملComparison of breath hold and free breathing respiratory triggered retrospectively cardiac gated cine steady-state free precession (RT-SSFP) imaging in adults
Background The cine steady-state free-precession (SSFP) is the standard sequence for left ventricular (LV) function evaluation. However, SSFP mandates uninterrupted RF excitations to maintain steady-state (SS) during suspended respiration. In patients who cannot perform breath-holds (BH), a respiratory triggered (RT) free breathing (FB) retrospectively cardiac gated cine SSFP sequence that driv...
متن کاملClinical validation of free breathing Respiratory Triggered Retrospectively Cardiac Gated Cine Steady-State Free Precession (RT-SSFP) imaging in sedated children
Background Cine steady-state free precession (SSFP) is the preferred sequence for ventricular function evaluation. However, SSFP demands uninterrupted RF excitation to maintain steady-state (SS) during suspended respiration. This is feasible in adults who can perform breath-holding (BH), but is difficult to accomplish in sedated or uncooperative children. To overcome this, many pediatric groups...
متن کاملBreast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE
INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 53 4 شماره
صفحات -
تاریخ انتشار 2005