Intense vasoconstriction in response to aspirate from stented saphenous vein aortocoronary bypass grafts.

نویسندگان

  • Kirsten Leineweber
  • Dirk Böse
  • Magdalene Vogelsang
  • Michael Haude
  • Raimund Erbel
  • Gerd Heusch
چکیده

OBJECTIVES We sought to identify soluble vasoconstrictor substances that are released during stent implantation into saphenous vein aortocoronary bypass grafts. BACKGROUND Atherosclerotic saphenous vein aortocoronary bypass grafts are particularly vulnerable to plaque rupture. Protection devices prevent particulate debris from being embolized. Additional soluble vasoconstrictor substances possibly also contribute to impaired microvascular perfusion. METHODS Peripheral venous blood (VB) and aspirate (AS) were obtained from 14 patients with a significant stenosis in a saphenous vein graft during stent implantation under protection with a distal balloon occlusion device. In five additional patients, arterial blood (AB) was also taken distal to the stented lesion before intervention. Vasomotor substances in VB, AB, and AS plasma were identified in a bioassay of rat mesenteric arteries with intact (+E) and denuded endothelium (-E). Vasoconstriction was normalized to that induced by potassium chloride depolarization (100%). RESULTS Venous blood, AB, and AS plasma induced maximum vasoconstriction within six minutes. The AS plasma induced a vasoconstriction of 138 +/- 13% (-E) and 87 +/- 14% (+E); VB, of 70 +/- 14% (-E) and 23 +/- 4% (+E); and AB plasma obtained before intervention, of 49 +/- 9% (-E) and 36 +/- 8% (+E). The vasoconstrictor potency of AS plasma in endothelium-denuded vessels was related to the severity of anginal symptoms, angiographic stenosis severity, plaque volume, and plaque burden as determined by intravascular ultrasound. The AS plasma-induced vasoconstriction was largely attenuated by combined serotonin/5-hydroxytryptamine (5-HT)(2A/2C)- and 5-HT(1A/1B)-receptor blockade and eliminated by additional thromboxane A2 thromboxane-prostanoid (TP)-receptor blockade. CONCLUSIONS Stent implantation releases, apart from and in addition to particulate debris, soluble vasoconstrictor substances that possibly contribute to impaired microvascular perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vasoconstrictor potential of coronary aspirate from patients undergoing stenting of saphenous vein aortocoronary bypass grafts and its pharmacological attenuation.

RATIONALE Stent implantation into atherosclerotic plaques releases, apart from particulate debris, soluble substances that contribute to impaired microvascular perfusion. OBJECTIVE To quantify the release of vasoconstrictors and to determine the efficacy of coronary dilators to attenuate their action. METHODS AND RESULTS Using a distal protection/aspiration device, coronary arterial blood w...

متن کامل

Aspirate from human stented saphenous vein grafts induces epicardial coronary vasoconstriction and impairs perfusion and left ventricular function in rat bioassay hearts with pharmacologically induced endothelial dysfunction

Stent implantation into aortocoronary saphenous vein grafts (SVG) releases particulate debris and soluble vasoactive mediators, for example, serotonin. We now analyzed effects of the soluble mediators released into the coronary arterial blood during stent implantation on vasomotion of isolated rat epicardial coronary artery segments and on coronary flow and left ventricular developed pressure i...

متن کامل

Clinical/Translational Research Vasoconstrictor Potential of Coronary Aspirate From Patients Undergoing Stenting of Saphenous Vein Aortocoronary Bypass Grafts and Its Pharmacological Attenuation

Rationale: Stent implantation into atherosclerotic plaques releases, apart from particulate debris, soluble substances that contribute to impaired microvascular perfusion. Objective: To quantify the release of vasoconstrictors and to determine the efficacy of coronary dilators to attenuate their action. Methods and Results: Using a distal protection/aspiration device, coronary arterial blood wa...

متن کامل

TRANSLATIONAL PHYSIOLOGY Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris

Kleinbongard P, Baars T, Möhlenkamp S, Kahlert P, Erbel R, Heusch G. Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris. Am J Physiol Heart Circ Physiol 305: H1222–H1229, 2013. First published August 9, 2013; doi:10.1152/ajpheart.00358.2013.—Stent implantation into atherosclerotic coronary arteries releases particulate deb...

متن کامل

Multiple aortocoronary bypass saphenous vein graft aneurysms in a 77-year-old man.

Aneurysms of aortocoronary saphenous vein bypass grafts are a rare complication of coronary artery bypass grafts. The authors report the incidental finding of four aneurysms in two aortocoronary saphenous vein bypass grafts in a 77-year-old man with progressive generalized weakness, left facial drooping, and digitalis toxicity. A brief review of the literature on this rare condition is also pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2006