Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study
نویسندگان
چکیده
Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.
منابع مشابه
Segmentation and Size Measurement of Polyps in CT Colonography
Virtual colonoscopy is a relatively new method for the detection of colonic polyps. Their size, which is measured from reformatted CT images, mainly determines diagnosis. We present an automatic method for measuring the polyp size. The method is based on a robust segmentation method that grows a surface patch over the entire polyp surface starting from a seed. Projection of the patch points alo...
متن کاملComputed tomographic virtual colonoscopy computer-aided polyp detection in a screening population.
BACKGROUND & AIMS The sensitivity of computed tomographic (CT) virtual colonoscopy (CT colonography) for detecting polyps varies widely in recently reported large clinical trials. Our objective was to determine whether a computer program is as sensitive as optical colonoscopy for the detection of adenomatous colonic polyps on CT virtual colonoscopy. METHODS The data set was a cohort of 1186 s...
متن کاملRobust Large Scale Prone-Supine Polyp Matching Using Local Features: A Metric Learning Approach
Computer aided detection (CAD) systems have emerged as noninvasive and effective tools, using 3D CT Colonography (CTC) for early detection of colonic polyps. In this paper, we propose a robust and automatic polyp prone-supine view matching method, to facilitate the regular CTC workflow where radiologists need to manually match the CAD findings in prone and supine CT scans for validation. Apart ...
متن کاملAn open source implementation of colon CAD in 3D Slicer
Most colon CAD (computer aided detection) software products, especially commercial products, are designed for use by radiologists in a clinical environment. Therefore, those features that effectively assist radiologists in finding polyps are emphasized in those tools. However, colon CAD researchers, many of whom are engineers or computer scientists, are working with CT studies in which polyps h...
متن کاملUsing Optical Flow Fields for Polyp Detection in Virtual Colonoscopy
Since the introduction of Computed Tomographic Colonography (CTC), research has mainly focused on visualization and navigation techniques. Recently, efforts have shifted towards computer aided detection (CAD) of polyps. We propose a new approach to CAD in CT images that attempts to model the way a radiologist recognizes a polyp using optical flow fields (OFF). Features extracted from OFFs are u...
متن کامل