Effects of a circulating-water garment and forced-air warming on body heat content and core temperature.

نویسندگان

  • Akiko Taguchi
  • Jebadurai Ratnaraj
  • Barbara Kabon
  • Neeru Sharma
  • Rainer Lenhardt
  • Daniel I Sessler
  • Andrea Kurz
چکیده

BACKGROUND Forced-air warming is sometimes unable to maintain perioperative normothermia. Therefore, the authors compared heat transfer, regional heat distribution, and core rewarming of forced-air warming with a novel circulating-water garment. METHODS Nine volunteers were each evaluated on two randomly ordered study days. They were anesthetized and cooled to a core temperature near 34 degrees C. The volunteers were subsequently warmed for 2.5 h with either a circulating-water garment or a forced-air cover. Overall, heat balance was determined from the difference between cutaneous heat loss (thermal flux transducers) and metabolic heat production (oxygen consumption). Average arm and leg (peripheral) tissue temperatures were determined from 18 intramuscular needle thermocouples, 15 skin thermal flux transducers, and "deep" hand and foot thermometers. RESULTS Heat production (approximately 60 kcal/h) and loss (approximately 45 kcal/h) were similar with each treatment before warming. The increases in heat transfer across anterior portions of the skin surface were similar with each warming system (approximately 65 kcal/h). Forced-air warming had no effect on posterior heat transfer, whereas circulating-water transferred 21+/-9 kcal/h through the posterior skin surface after a half hour of warming. Over 2.5 h, circulating water thus increased body heat content 56% more than forced air. Core temperatures thus increased faster than with circulating water than forced air, especially during the first hour, with the result that core temperature was 1.1 degrees +/- 0.7 degrees C greater after 2.5 h (P < 0.001). Peripheral tissue heat content increased twice as much as core heat content with each device, but the core-to-peripheral tissue temperature gradient remained positive throughout the study. CONCLUSIONS The circulating-water system transferred more heat than forced air, with the difference resulting largely from posterior heating. Circulating water rewarmed patients 0.4 degrees C/h faster than forced air. A substantial peripheral-to-core tissue temperature gradient with each device indicated that peripheral tissues insulated the core, thus slowing heat transfer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two different temperature maintenance strategies during open abdominal surgery: upper body forced-air warming versus whole body water garment.

BACKGROUND A new system has been developed that circulates warm water through a whole body garment worn by the patient during surgery. In this study the authors compared two different strategies for the maintenance of intraoperative normothermia. One strategy used a new water garment warming system that permitted active warming of both the upper and lower extremities and the back. The other str...

متن کامل

Circulating-water garment or the combination of a circulating-water mattress and forced-air cover to maintain core temperature during major upper-abdominal surgery.

BACKGROUND A recent heat-balance study in volunteers suggested that greater efficacy of circulating-water garments (CWGs) results largely from increased heat transfer across the posterior skin surface since heat transfer across the anterior skin surface was similar with circulating-water and forced-air. We thus tested the hypothesis that the combination of a circulating-water mattress (CWM) and...

متن کامل

Warming by resistive heating maintains perioperative normothermia as well as forced air heating.

BACKGROUND Even mild perioperative hypothermia is associated with several severe adverse effects. Resistive heating has possible advantages compared with other active warming systems because it can heat several fields independently. To assess this new warming system, we measured core temperature in patients during surgery who were warmed with circulating water mattresses, forced air covers or r...

متن کامل

Water warming garment versus forced air warming system in prevention of intraoperative hypothermia during liver transplantation: a randomized controlled trial [ISRCTN32154832]

BACKGROUND: The authors compared two strategies for the maintenance of intraoperative normothermia during orthotopic liver transplantation (OLT): the routine forced-air warming system and the newly developed, whole body water garment. METHODS: In this prospective, randomized and open-labelled study, 24 adult patients were enrolled in one of two intraoperative temperature management groups durin...

متن کامل

Conductive heat exchange with a gel-coated circulating water mattress.

The use of forced-air warming is associated with costs for the disposable blankets. As an alternative method, we studied heat transfer with a reusable gel-coated circulating water mattress placed under the back in eight healthy volunteers. Heat flux was measured with six calibrated heat flux transducers. Additionally, mattress temperature, skin temperature, and core temperature were measured. W...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 100 5  شماره 

صفحات  -

تاریخ انتشار 2004