Incorrect needle position during lumbar epidural steroid administration: inaccuracy of loss of air pressure resistance and requirement of fluoroscopy and epidurography during needle insertion.

نویسندگان

  • Walter S Bartynski
  • Stephen Z Grahovac
  • William E Rothfus
چکیده

Loss of air pressure resistance leads to a high rate (25.7%) of inaccurate needle-tip placement in the posterior soft tissues of the back during lumbar epidural steroid administration employing a 20-gauge Tuohy needle. Imaging and epidurogram are essential for confident identification of the lumbar epidural space to enable accurate location of steroid administration. Studies assessing efficacy of lumbar epidural steroid injection and individual patient treatments should ensure location of administration with epidurogram to enhance the validity of results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of fluoroscopy in cervical epidural steroid injections: an analysis of contrast dispersal patterns.

STUDY DESIGN A multicenter, retrospective analysis of cervical epidurograms. OBJECTIVES To determine the effectiveness of the loss of resistance (LOR) technique in identifying the cervical epidural space. To delineate the pattern of epidural contrast spread during cervical epidural steroid injections. BACKGROUND Previous studies have shown that if performed without fluoroscopy, the LOR tech...

متن کامل

Appearance of plica mediana dorsalis during epidurography.

To the Editor: The plica mediana dorsalis (PMD) is thought to be a band of connective tissue, which divides the epidural space at the dorsal midline. Existence of the PMD has been controversial since its first description in 1963 (1). The PMD has been regarded as a potential cause for unilateral epidural blockade (2, 3). For purpose of discussion, we present a case of a patient who presented fo...

متن کامل

Use of Fluoroscopy for Interlaminar Lumbar Epidural Injection: Is Confirmation with Epidurogram Necessary?

We compared the loss of resistance (LOR) technique and fluoroscopy with the LOR technique, fluoroscopy, and epidurography for interlaminar epidural injection. A total of 371 patients with symptomatic lumbosacral radiculopathy were enrolled; 17 had a history of allergy to iodinated contrast medium or seafood. Each patient was given an oral steroid before and after the procedure. A Tuohy needle w...

متن کامل

Loss of resistance to saline reduces responses accompanying spinal needle insertion during institution of 'needle-through-needle' combined spinal-epidural analgesia.

Normal saline or air is used to identify loss of resistance during identification of the epidural space for combined spinal-epidural analgesia. Following epidural needle placement using air for loss of resistance, up to 80% of parturients move, grimace, vocalise or experience paraesthesia or dysaesthesia during subsequent dural puncture by a spinal needle. We compared the effects of saline vers...

متن کامل

CT fluoroscopy-guided epidural injections: technique and results.

Lumbar epidural injections are typically performed blindly or with fluoroscopic guidance. CT fluoroscopy (CTF) can be used to guide needle placement precisely and rapidly, allowing visualization of the optimal needle path and identifying potential problems such as severe stenosis and synovial cysts before needle insertion. Operator and patient radiation dose is minimal when using the intermitte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2005