Validation of SenseWear Armband and ActiHeart monitors for assessments of daily energy expenditure in free-living women with chronic obstructive pulmonary disease

نویسندگان

  • Nighat Farooqi
  • Frode Slinde
  • Lena Håglin
  • Thomas Sandström
چکیده

To provide individually adapted nutritional support to patients with chronic obstructive pulmonary disease (COPD), objective and reliable methods must be used to assess patient energy requirements. The aim of this study was to validate the use of SenseWear Armband (SWA) and ActiHeart (AH) monitors for assessing total daily energy expenditure (TEE) and activity energy expenditure (AEE) and compare these techniques with the doubly labeled water (DLW) method in free-living women with COPD. TEE and AEE were measured in 19 women with COPD for 14 days using SWAs with software version 5.1 (TEESWA5, AEESWA5) or 6.1 (TEESWA6, AEESWA6) and AH monitors (TEEAH, AEEAH), using DLW (TEEDLW) as the criterion method. The three methods were compared using intraclass correlation coefficient (ICC) and Bland-Altman analyses. The mean TEE did not significantly differ between the DLW and SWA5.1 methods (-21 ± 726 kJ/day; P = 0.9), but it did significantly differ between the DLW and SWA6.1 (709 ± 667 kJ/day) (P < 0.001) and the DLW and AH methods (709 ± 786 kJ/day) (P < 0.001). Strong agreement was observed between the DLW and TEESWA5 methods (ICC = 0.76; 95% CI 0.47-0.90), with moderate agreements between the DLW and TEESWA6 (ICC = 0.66; 95% CI 0.02-0.88) and the DLW and TEEAH methods (ICC = 0.61; 95% CI 0.05-0.85). Compared with the DLW method, the SWA5.1 underestimated AEE by 12% (P = 0.03), whereas the SWA6.1 and AH monitors underestimated AEE by 35% (P < 0.001). Bland-Altman plots revealed no systematic bias for TEE or AEE. The SWA5.1 can reliably assess TEE in women with COPD. However, the SWA6.1 and AH monitors underestimate TEE. The SWA and AH monitors underestimate AEE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and Usability of Low-Cost Accelerometers for Internet-Based Self-Monitoring of Physical Activity in Patients With Chronic Obstructive Pulmonary Disease

BACKGROUND The importance of regular physical activity for patients with chronic obstructive pulmonary disease (COPD) is well-established. However, many patients do not meet the recommended daily amount. Accelerometers might provide patients with the information needed to increase physical activity in daily life. OBJECTIVE Our objective was to assess the validity and usability of low-cost Int...

متن کامل

Effect of Home-based Pulmonary Rehabilitation on Daily Activity of Patients with Chronic Obstructive Pulmonary Disease

Background: Pulmonary rehabilitation is an important part of treatment in patients with COPD (Chronic Obstructive Pulmonary Disease) with the goal of achieving and maintaining maximum functional independence since this disease causes symptoms including fatigue, and consequently decrease in daily living activity. Aim: To determine the effect of home-based pulmonary rehabilitation on daily living...

متن کامل

Validity of Six Activity Monitors in Chronic Obstructive Pulmonary Disease: A Comparison with Indirect Calorimetry

Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7 years, FEV(1) 54±18%predict...

متن کامل

Energy expenditure during daily activities as measured by two motion sensors in patients with COPD.

BACKGROUND In patients with chronic obstructive pulmonary disease (COPD), energy expenditure (EE) assessment during the performance of daily activities is not yet studied in depth. The aim of this study was to determine which daily activities are more demanding to patients with COPD and to compare the accuracy of EE estimation given by the pedometer Digiwalker SW701 (DW) and the multisensor Sen...

متن کامل

Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

INTRODUCTION The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. METHODS We studied 26 (15F/11M) human subjects wea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2013