A Study on the Condition Monitoring of Transmission Line by On-line Circuit Parameter Measurement

نویسندگان

  • Jin Rak Lee
  • Young Jun Ko
چکیده

An on-line condition monitoring method for transmission line is proposed using electrical circuit theory and IT technology in this paper. It is reasonable that the circuit parameters such as resistance (R), inductance (L), conductance (g) and capacitance (C) of a transmission line expose the electrical conditions and physical state of the line. Those parameters can be calculated from the linear equation composed of voltages and currents measured by synchro-phasor measurement technique at both end of the line. A set of linear voltage drop equations containing four terminal constants ( • • • • D , C , B , A ) are mathematical models of the transmission line circuits. At least two sets of those linear equations are established from different operation condition of the line, they may mathematically yield those circuit parameters of the line. The conditions of line connectivity including state of connecting parts or contacting parts of the switching device may be monitored by resistance variations during operation. The insulation conditions of the line can be monitored by conductance (g) and capacitance (C) measurements. Together with other condition monitoring devices such as partial discharge, sensors and visual sensing device etc., they may give useful information to monitor out any incipient symptoms of faults. The prototype of hardware system has been developed and tested through laboratory level simulated transmission lines. The test has shown enough evident to put the proposed method to practical uses. Keywords—Transmission Line, Condition Monitoring, Circuit Parameters, Synchro-phasor Measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Miniaturized High-Pass Filter Based on Balanced Composite Right-Left Handed Transmission Line Using Meander Spiral Complementary Split Ring Resonators

In this paper, a compact high-pass filter (HPF) with a sharp rejection response based on the balanced composite right-left handed (CRLH) transmission line (TL) concept is proposed. A series LC resonator using an interdigital capacitor and meander lines is designed. Also, a meander spiral complementary split ring resonator (MSCSRR) is used to realize the parallel LC resonator. The high-pass filt...

متن کامل

الگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU

A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...

متن کامل

Fault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method

In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

Design of a Two Octave Gysel Power-Divider Using DGS and DMS

This paper proposes a two way L and S band Gysel power divider/combiner that uses line to ground resistors. Step by step methods to obtain a wide isolation and transmission bandwidth are presented. A design that uses five resistors is selected and optimized based on Quasi Newton method. Then the Defected Microstrip Structure (DMS) and Defected Ground Structure (DGS) is used to obtain better tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013