Aortic distensibility and coronary artery bypass graft patency
نویسندگان
چکیده
BACKGROUND Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determined aortic distensibility with the patency rates of coronary bypass grafts METHODS The study was conducted in the Cardiology department of the Applied Research Centre for Health of Uludağ University. The coronary angiograms of 53 consecutive coronary bypass patients were analysed retrospectively. Aortic distensibility was calculated using the formula: 2 x (change in aortic diameter)/(diastolic aortic diameter) x (change in aortic pressure). The number of stenosed and patent bypass grafts and the patient characteristics like age, risk factors were noted. RESULTS There were 44 male (83%) and 9 female (17%) cases. Eighteen cases had only one saphenous vein grafting. The number of cases with two, three and four saphenous grafting were 18, 11 and 1; respectively. In the control angiograms the number of cases with one, two, three and four saphenous vein graft obstruction were 15 (31.3%), 7 (14.6%), 1 (2.1%) and 1 (2.1%) respectively. The aortic distensibility did not differ in cases with and without saphenous graft occlusion (p > 0.05). Also left internal mammary artery (LIMA) graft patency was not related to the distensibility of the aorta (p > 0.05). We also evaluated the data for cut-off values of 50 and 70 mmHg of pulse pressure and did not see any significant difference between the groups in terms of saphenous or LIMA grafts. CONCLUSION In this study we failed to show association of angiographically determined aortic distensibility with coronary bypass graft patency in consecutive 53 patients with coronary artery bypass graft surgery (CABG).
منابع مشابه
Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery
Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...
متن کاملThe Right Gastroepiploic Artery Graft for Coronary Artery Bypass Grafting: A 30-Year Experience
Throughout its 30-year history, the right gastroepiploic artery (GEA) has been useful for in situ grafts in coronary artery bypass grafting (CABG). The early graft patency rate is high, and the late patency rate has improved by using the skeletonized GEA graft and proper target selection, which involves having a target coronary artery with a tight >90% stenosis. Total arterial revascularization...
متن کاملThirty-year patency of a coronary sequential venous bypass graft.
BACKGROUND The optimal conduit of second choice in surgical coronary revascularization remains a matter of debate. Radial artery grafts are believed to have a better patency rate than the saphenous vein grafts, although no conclusive results have been reported. This report describes the late result of a coronary revascularization with sequential venous bypass performed 30 years earlier. METHO...
متن کاملFree right internal thoracic artery as a second arterial conduit: modification of proximal anastomosis for improvement of graft patency.
The applicability of the right internal thoracic artery (RITA) for coronary artery bypass grafting is higher when used as a free graft than as a pedicled graft. However, the technical difficulty of directly connecting the proximal end of the free RITA to the much larger aorta leads to poor patency. To overcome this technical limitation, we have used a modification that places the proximal end o...
متن کاملUsefulness of Cardiac Computed Tomography in the Diagnosis of Prosthetic Coronary Artery Graft with Interposition Procedure
An 80-year-old Japanese man was admitted with orthopnea and pitting edema of both lower legs. We diagnosed congestive heart failure (CHF) on the basis of a chest X-ray and an echocardiogram. An electrocardiogram showed a heart rate of 120 beats/min with atrial fibrillation rhythm (Af). The patient developed aortic valve failure and destruction of the base of right coronary artery (RCA) due to i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Cardiothoracic Surgery
دوره 4 شماره
صفحات -
تاریخ انتشار 2009