Prokaryotic RNA preparation methods useful for high density array analysis: comparison of two approaches.

نویسندگان

  • C Rosenow
  • R M Saxena
  • M Durst
  • T R Gingeras
چکیده

High density oligonucleotide arrays have been used extensively for expression studies of eukaryotic organisms. We have designed a prokaryotic high density oligonucleotide array using the complete Escherichia coli genome sequence to monitor expression levels of all genes and intergenic regions in the genome. Because previously described methods for preparing labeled target nucleic acids are not useful for prokaryotic cell analysis using such arrays, a mRNA enrichment and direct labeling protocol was developed together with a cDNA synthesis protocol. The reproducibility of each labeling method was determined using high density oligonucleotide probe arrays as a read-out methodology and the expression results from direct labeling were compared to the expression results from the cDNA synthesis. About 50% of all annotated E.coli open reading frames are observed to be transcribed, as measured by both protocols, when the cells were grown in rich LB medium. Each labeling method individually showed a high degree of concordance in replica experiments (95 and 99%, respectively), but when each sample preparation method was compared to the other, approximately 32% of the genes observed to be expressed were discordant. However, both labeling methods can detect the same relative gene expression changes when RNA from IPTG-induced cells was labeled and compared to RNA from uninduced E.coli cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Radial and Halbach Array PMLSM by Employing 2-D Electromagnetic Finite Element Analysis

The replacement of steam catapults with electromagnetic ones is becoming an overwhelming trend in aircraft launch systems. The Electromagnetic Aircraft Launch System (EMALS) offers significant benefits to the aircraft, ship, personnel, and operational capabilities. EMALS has such advantages as high thrust, good controllability, reusable, etc., as a launching motor, a double-side plate Permanent...

متن کامل

Comparison of Sperm Telomere Length between Two Sperm Selection Procedures: Density Gradient Centrifugation and Zeta Potential

Background: Telomeres are particular sequences of DNA located at the end of the eukaryotic chromosomes that are essential for genome integrity. Telomere length in spermatozoa differs among males, as well as spermatozoa. Also, decreased telomere length in spermatozoa of infertile men is associated with the reduction of fertility potential and embryo quality. Density gradient centrifugation (DGC)...

متن کامل

TAAPP: Tiling Array Analysis Pipeline for Prokaryotes

High-density tiling arrays provide closer view of transcription than regular microarrays and can also be used for annotating functional elements in genomes. The identified transcripts usually have a complex overlapping architecture when compared to the existing genome annotation. Therefore, there is a need for customized tiling array data analysis tools. Since most of the initial tiling arrays ...

متن کامل

A comparison of RNA-Seq and high-density exon array for detecting differential gene expression between closely related species

RNA-Seq has emerged as a revolutionary technology for transcriptome analysis. In this article, we report a systematic comparison of RNA-Seq and high-density exon array for detecting differential gene expression between closely related species. On a panel of human/chimpanzee/rhesus cerebellum RNA samples previously examined by the high-density human exon junction array (HJAY) and real-time qPCR,...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nucleic acids research

دوره 29 22  شماره 

صفحات  -

تاریخ انتشار 2001