Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants

نویسندگان

  • Hongmei Hu
  • Mathias Dietz
چکیده

In patients with bilateral cochlear implants (CIs), pairing matched interaural electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, and spatial release from masking. Because clinical procedures typically do not include patient-specific interaural electrode pairing, it remains the case that each electrode is allocated to a generic frequency range, based simply on the electrode number. Two psychoacoustic techniques for determining interaurally paired electrodes have been demonstrated in several studies: interaural pitch comparison and interaural time difference (ITD) sensitivity. However, these two methods are rarely, if ever, compared directly. A third, more objective method is to assess the amplitude of the binaural interaction component (BIC) derived from electrically evoked auditory brainstem responses for different electrode pairings; a method has been demonstrated to be a potential candidate for bilateral CI users. Here, we tested all three measures in the same eight CI users. We found good correspondence between the electrode pair producing the largest BIC and the electrode pair producing the maximum ITD sensitivity. The correspondence between the pairs producing the largest BIC and the pitch-matched electrode pairs was considerably weaker, supporting the previously proposed hypothesis that whilst place pitch might adapt over time to accommodate mismatched inputs, sensitivity to ITDs does not adapt to the same degree.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of mismatched place-of-stimulation on binaural fusion and lateralization in bilateral cochlear-implant users.

Bilateral cochlear implants (CIs) have provided some success in improving spatial hearing abilities to patients, but with large variability in performance. One reason for the variability is that there may be a mismatch in the place-of-stimulation arising from electrode arrays being inserted at different depths in each cochlea. Goupell et al. [(2013b). J. Acoust. Soc. Am. 133(4), 2272-2287] show...

متن کامل

Lateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users.

Bilateral cochlear implant (BiCI) users have shown variability in interaural time difference (ITD) sensitivity at different places along the cochlea. This paper investigates perception of multi-electrode binaural stimulation to determine if auditory object formation (AOF) and lateralization are affected by variability in ITD sensitivity when a complex sound is encoded with multi-channel process...

متن کامل

Sound Localization and Interaural Time Sensitivity with Bilateral Cochlear Implants

Bilateral cochlear implantation is becoming more common as clinicians attempt to provide better sound-source localization and speech reception in noise for cochlear implant (CI) users. While some improvement over the abilities of monolateral implantees has been documented, bilateral performance for CI users is far from that achieved with normal hearing. Identifying factors that limit bilateral ...

متن کامل

Lateralization of Interaural Level Differences in Multi-Channel Electrical Stimulation

Lateralization of Interaural Level Differences in Multi-Channel Electrical Stimulation Olga Stakhovskaya, Tanvi Thakkar, Matthew Goupell University of Maryland College Park Background Improved sound localization is one of the benefits associated with use of bilateral cochlear implants (CIs). Modern speech processors cannot reliably encode all of the localization cues available to normal-hearing...

متن کامل

Auditory Model-Based Sound Direction Estimation With Bilateral Cochlear Implants

Users of bilateral cochlear implants (CIs) show above-chance performance in localizing the source of a sound in the azimuthal (horizontal) plane; although localization errors are far worse than for normal-hearing listeners, they are considerably better than for CI listeners with only one implant. In most previous studies, subjects had access to interaural level differences and to interaural tim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015