Identification and quantification of hemoglobins A, F, S, and C by automated chromatography.

نویسندگان

  • C Papadea
  • J C Cate
چکیده

The Bio-Rad Variant Hemoglobin Testing System is an automated HPLC analyzer marketed with a Beta-thalassemia Short Program to quantify hemoglobins (Hbs) F and A2 and assist in detecting Hbs A, S, C, D, and E. We evaluated this system to replace several traditional methods for Hb in our hospital laboratory. Analytical performance relevant to quantifying Hbs A, S, C, and F was assessed with blood samples obtained from our local patient population. Studies of precision (CVs < 3%) and analytical limits (% of total Hb) of Hbs A (2-86%), F (1-89%), S (5-90%), and C (3-92%) demonstrated results comparable with or exceeding those of traditional methods. Results for patients' samples (n) for Hbs A (107), F (157), S (128), and C (27) correlated well (r > 0.93) with results by traditional methods. The satisfactory performance and efficiency led us to implement this system for routine quantification of clinically significant Hbs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of hemoglobins S, C, and F by a magnetic affinity immunoassay.

This magnetic affinity immunoassay (MAIA) quantifies hemoglobins (Hb) S, C, and F in hemolysates from adults or newborns. Monospecific antisera to the hemoglobins are covalently conjugated to magnetic beads and reacted with the corresponding 125I-labeled hemoglobin. After centrifugation to separate the free and antibody-bound 125I-labeled hemoglobin, the amount of radioactive hemoglobin in the ...

متن کامل

The validation of an automated liquid chromatography system for the diagnosis of thalassemias and hemoglobinopathies.

Accurate and precise hemoglobin separation and the quantitation of Hb A2 and Hb F are essential for the diagnosis of the thalassemias and hemoglobinopathies. Presented in this study is the validation of the the Hb A2 assay of the HbGold analyzer, a fully automated liquid chromatography system for hemoglobin separation and quantitation. Variability of Hb A2 quantitation was quite low; the CV's o...

متن کامل

Identification and quantification of hemoglobins A2 and Barts with an enzyme-labeled immunosorbent assay.

The presence and quantity of hemoglobins Barts and A2 in hemolysates from normal donors and individuals with alpha- and beta-thalassemia trait, respectively, were determined with an enzyme-labeled immunosorbent assay (ELISA). This technique requires the incorporation of monospecific antisera capable of specifically reacting only with these hemoglobins, e.g., with the delta chain of Hb A2 and ga...

متن کامل

Improved rapid procedure for simultaneous determinations of hemoglobins A1a, A1b, A1c, F, C, and S, with indication for acetylation or carbamylation by cation-exchange liquid chromatography.

Although the clinical utility of glycohemoglobin (HbA1c) as an indicator of blood glucose control is generally accepted, the use of cation-exchange liquid chromatography for its quantification is controversial, given numerous studies that show no correlation between HbA1c and other indicators of blood glucose control in uremic subjects. We report a specific cation-exchange liquid-chromatographi...

متن کامل

Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study

In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1996