Reference values of gait using APDM movement monitoring inertial sensor system
نویسندگان
چکیده
Normal gait data reported show variability depending on specific equipment and techniques. Reference values of initial contact angle (ICA) and toe-off angle (TOA) are still lacking. We present a normative gait database of 292 healthy adults using the APDM Movement Monitoring inertial sensor system across a large age span of adulthood. Data were collected as participants completed a walk test for 2 min. Normalization was conducted and two factors were extracted by a factor analysis. Six reference gait variables under each factor were presented and the impacts of age, gender and BMI were evaluated by MANOVA and ANCOVA. ICA and TOA were highly correlated with speed and stride length. ICA was significantly larger in men, whereas larger TOA could be observed in women in all age groups but could not achieve significant difference. Overweight and obese adults walked at significantly lower speed, shorter stride length, reduced cadence and longer gait cycle duration. TOA was smaller in the obese group. However, the differences in ICA were not significant. Reference gait values described herein were valuable for identifying and interpreting gait phenomena using APDM®, contributing to rehabilitation of gait dysfunction.
منابع مشابه
Validity and repeatability of inertial measurement units for measuring gait parameters.
Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this s...
متن کاملAutomatic detection of inertial sensor orientation for movement analysis in Parkinson’s disease
To analyze the gait of Parkinson's patients and to objectively rate their disease stage development all over the day, low cost inertial sensors can be used. A current challenge is to deal with the potentially unknown sensor position. When measurements are recorded over a longer time period and in an unsupervised environment, sensor position can vary. Therefore, it is necessary to detect the ori...
متن کاملA System for estimating Spatio-Temporal Gait Parameters and Pelvis Kinematics
The estimation of the spatio-temporal Gait Parameters (GP) and Pelvis Kinematics (PK) is of primary importance in both physical activity monitoring and clinical contexts. It becomes ever more necessary to have low-cost and user-friendly tools that enable this type of analysis. In this work, we present a waist-worn system created with an inertial measurement units (IMU), comprising a 3D accelero...
متن کاملAn Fes-assisted Gait Training System for Hemiplegic Stroke Patients Based on Inertial Sensors
An inertial sensor mounted on the foot of the affected body side represents an alternative to traditional foot switches in Functional Electrical Stimulation (FES)assisted gait rehabilitation systems. The inertial sensor consisting of 3 gyroscopes and 3 accelerometers can be utilised to detect gait phases which can be applied to synchronise the electrical stimulation with the gait. Additionally,...
متن کاملPhysical Behavior in Older Persons during Daily Life: Insights from Instrumented Shoes
Activity level and gait parameters during daily life are important indicators for clinicians because they can provide critical insights into modifications of mobility and function over time. Wearable activity monitoring has been gaining momentum in daily life health assessment. Consequently, this study seeks to validate an algorithm for the classification of daily life activities and to provide...
متن کامل