Is the Peak-to-Mean Pressure Gradient Ratio Useful for Assessment of Aortic Valve Prosthesis Obstruction?

نویسندگان

  • Maryam Esmaeilzadeh
  • Ahmad Mirdamadi
  • Mozhgan Parsaee
  • Anita Sadeghpour
  • Majid Maleki
  • Hooman Bakhshandeh Abkenar
چکیده

BACKGROUND The evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. Doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. However, Doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. The peak-to-mean pressure decrease ratio is a load-independent measure, which was previously used for the detecting and grading of aortic valve stenosis. We assessed the usefulness of this method for the evaluation of aortic valve prosthesis obstruction. METHODS One hundred fifty-four patients with aortic valve prostheses were included in this study. Transthoracic and transesophageal echocardiographic examinations were performed in all the patients. Peak velocity and velocity time integral of the aortic valve and left ventricular outflow tract, peak and mean aortic valve pressure gradients, peak-to-mean pressure gradient ratio, and time velocity integral (TVI) index were measured. RESULTS There was a significant relation between the TVI index (p value < 0.001) and aortic prosthesis obstruction. A TVI index < 0.2 had a sensitivity of 71% and specificity of 100% for the detection of aortic valve prosthesis obstruction. However, no significant relation was found between the peak-to-mean pressure ratio and aortic valve prosthesis obstruction (p value = 0.09). CONCLUSION Although the peak-to-mean pressure gradient (PG/MG) ratio is a simple, quick, and load-independent method which may be useful for the grading of aortic valve stenosis, it is poorly associated with aortic valve prosthesis obstruction. The TVI index is a useful measure for the detection of aortic prosthesis obstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitral prosthesis malfunction. Comparative Doppler echocardiographic studies of mitral prostheses before and after replacement.

To assess the influence of mitral prosthesis malfunction on various Doppler echocardiographic indexes, we studied the changes in the peak mitral flow velocity during early diastolic filling phase (Vmax), the mean transprosthesis pressure drop from the simplified Bernoulli equation, the mitral valve area by the pressure half-time method, and the left ventricular isovolumic relaxation time in 15 ...

متن کامل

Delayed Time to Peak Velocity Is Useful for Detecting Severe Aortic Stenosis

BACKGROUND Time to peak velocity (TPV) is an echocardiographic variable that can be easily measured and reflects a late peaking murmur, a classic physical finding suggesting severe aortic stenosis (AS). The aim of this study was to investigate the usefulness of TPV to evaluate AS severity. METHODS AND RESULTS This study included 700 AS patients, whose aortic valve area (AVA) was <1.5 cm2, and...

متن کامل

Non-invasive estimation of the mean pressure difference in aortic stenosis by Doppler ultrasound.

The mean pressure difference across the valve in aortic stenosis is an indicator of the severity of the obstruction to flow. Non-invasive determination of the mean pressure gradient by Doppler ultrasonography is, however, complicated by the squared relation between instantaneous velocities and pressure differences. The validity of a new simple formula for calculation of the mean pressure differ...

متن کامل

Round Valve in an Oval Hole

Progressive narrowing of the aortic valve orifice eventually leads to limitations in cardiac output and myocardial blood flow, particularly during exercise or other physiological stress. The pressure gradient across the stenotic aortic valve is a useful and reproducible measure of the severity of the stenosis in most patients. The mainstay of therapy for aortic stenosis is relief of the fixed o...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2010