[Evaluation of an adaptive filter for CT under low-CNR condition: comparison with linear filter].
نویسندگان
چکیده
The use of an adaptive filter for CT images is becoming a common procedure and is said to reduce image noise while preserving sharpness and helping to reduce the required X-ray dose. Although many reports support this view, the validity of such evaluations is arguable. When the linearity of a system is in question, physical performance indexes should be measured under conditions similar to those of clinical use. Evaluations of diagnosis using clinical images may be fallible because the non-filtered image used as the reference might not have been optimally reconstructed. We have chosen simple, but commonly used, adaptive filters for our evaluation. As a reference for comparing performance, we designed linear filters that best approximate the noise characteristics of the adaptive filters. MTF is measured through observation of the edge-spread function. Clinical abdominal images are used to compare the performance of adaptive filters and linear filters. We conclude that the performance of the type of adaptive filter we have chosen is virtually the same as that of the linear filter, as long as the image quality of soft tissues is our interest. Both the noise SD and MTF are virtually the same if the contrast of the object is not substantially higher than 150 HU. Images of soft tissues obtained with the use of adaptive filters are also virtually the same as those obtained by linear filters. The edge-preservation characteristic of this adaptive filter is not observable for soft tissues.
منابع مشابه
TU-E-217BCD-04: Spectral Breast CT: Effect of Adaptive Filtration on CT Numbers, CT Noise, and CNR.
PURPOSE Photon counting spectral breast CT is feasible in part due to using an adaptive filter. An adaptive filter provides flat x-ray intensity profile and constant x-ray energy spectrum across detector surface, decreases required detector count rate, and eliminates beam hardening artifacts. However, the altered x-ray exposure profiles at the breast and detector surface may influence the distr...
متن کاملDesign and Experimental Evaluation of integrated orientation estimation algorithm Autonomous Underwater Vehicle Based on Indirect Complementary Filter
This paper aims is to design an integrated navigation system constituted by low-cost inertial sensors to estimate the orientation of an Autonomous Underwater Vehicle (AUV) during all phases of under water and surface missions. The proposed approach relied on global positioning system, inertial measurement unit (accelerometer & rate gyro), magnetometer and complementary filter technique. Complem...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملLow latency IIR digital filter design by using metaheuristic optimization algorithms
Filters are particularly important class of LTI systems. Digital filters have great impact on modern signal processing due to their programmability, reusability, and capacity to reduce noise to a satisfactory level. From the past few decades, IIR digital filter design is an important research field. Design of an IIR digital filter with desired specifications leads to a no convex optimization pr...
متن کاملComparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques
Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 65 1 شماره
صفحات -
تاریخ انتشار 2009