Comparison of the predictive accuracy of DNA array-based multigene classifiers across cDNA arrays and Affymetrix GeneChips.

نویسندگان

  • James Stec
  • Jing Wang
  • Kevin Coombes
  • Mark Ayers
  • Sebastian Hoersch
  • David L Gold
  • Jeffrey S Ross
  • Kenneth R Hess
  • Stephen Tirrell
  • Gerald Linette
  • Gabriel N Hortobagyi
  • W Fraser Symmans
  • Lajos Pusztai
چکیده

We examined how well differentially expressed genes and multigene outcome classifiers retain their class-discriminating values when tested on data generated by different transcriptional profiling platforms. RNA from 33 stage I-III breast cancers was hybridized to both Affymetrix GeneChip and Millennium Pharmaceuticals cDNA arrays. Only 30% of all corresponding gene expression measurements on the two platforms had Pearson correlation coefficient r >or= 0.7 when UniGene was used to match probes. There was substantial variation in correlation between different Affymetrix probe sets matched to the same cDNA probe. When cDNA and Affymetrix probes were matched by basic local alignment tool (BLAST) sequence identity, the correlation increased substantially. We identified 182 genes in the Affymetrix and 45 in the cDNA data (including 17 common genes) that accurately separated 91% of cases in supervised hierarchical clustering in each data set. Cross-platform testing of these informative genes resulted in lower clustering accuracy of 45 and 79%, respectively. Several sets of accurate five-gene classifiers were developed on each platform using linear discriminant analysis. The best 100 classifiers showed average misclassification error rate of 2% on the original data that rose to 19.5% when tested on data from the other platform. Random five-gene classifiers showed misclassification error rate of 33%. We conclude that multigene predictors optimized for one platform lose accuracy when applied to data from another platform due to missing genes and sequence differences in probes that result in differing measurements for the same gene.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and calibration of commercial oligonucleotide and custom cDNA microarrays.

We compared the accuracy of microarray measurements obtained with oligonucleotide arrays (GeneChip, Affymetrix) with a laboratory-developed cDNA array by assaying test RNA samples from an experiment using a paradigm known to regulate many genes measured on both arrays. We selected 47 genes represented on both arrays, including both known regulated and unregulated transcripts, and established re...

متن کامل

Development a New Technique Based on Least Square Method to Synthesize the Pattern of Equally Space Linear Arrays

Using the sampled data of a desired pattern is a common technique in pattern synthesizing of array factor (AF) of antenna arrays. Based on the obtained data matrix, Least Square Method (LSM) is used to calculate the exciting coefficient of array elements. The most important parameter, which involves the accuracy and complexity of calculation, is the sampling rate of the desired pattern. Classic...

متن کامل

Three-color cDNA microarrays with prehybridization quality control yield gene expression data comparable to that of commercial platforms.

Despite their lower cost and high content flexibility, a limitation of in-house-prepared arrays has been their susceptibility to quality control (QC) issues and lack of QC standards across laboratories. Therefore, we developed a novel three-color array system that allows prehybridization QC as well as the Matarray software to facilitate acquisition of accurate gene expression data. In this stud...

متن کامل

Bibliographie Juin 2008

An improved physico-chemical model of hybridization on high-density oligonucleotide microarrays .. 5 Comparison of Affymetrix GeneChip expression measures .................................................................... 5 Evaluation of methods for oligonucleotide array data via quantitative real-time PCR............................ 5 Gene expression levels assessed by oligonucleotide microa...

متن کامل

Affymetrix Whole-Transcript Human Gene 1.0 ST array is highly concordant with standard 3' expression arrays.

The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of molecular diagnostics : JMD

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2005