Substrate-labeled fluorescent immunoassay for phenytoin in human serum.

نویسندگان

  • R C Wong
  • J F Burd
  • R J Carrico
  • R T Buckler
  • J Thoma
  • R C Boguslaski
چکیده

A homogeneous substrate-labeled fluorescent immunoassay has been applied to the measurement of phenytoin concentrations in human serum. We coupled a fluorogenic enzyme substrate, galactosyl-umbelliferone, covalently to a derivative of phenytoin. Under assay conditions, this drug-substrate conjugate was nonfluorescent but became fluorescent upon hydrolysis catalyzed by bacterial beta-galactosidase. When antibody to phenytoin is bound to the drug-substrate conjugate, it is inactive as an enzyme substrate. Addition of phenytoin to competitive-binding reactions relieves the inactivation, and the resulting fluorescence is proportional to the phenytoin concentration. We validated the fluorescent immunoassay by comparing values for phenytoin obtained with this technique to those obtained by gas chromatography and by enzyme immunoassay (EMIT). All three methods correlated well. The major metabolite of phenytoin, 5-(p-hydroxyphenyl)-5-phenylhydantoin, and other drugs at concentrations expected in serum had no effect on the assay. The fluorescent immunoassay is rapid and simple to perform and requires only 2 microL of serum sample per test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dry-reagent strips for measuring phenytoin in serum.

A new reagent strip has been developed for measuring phenytoin in serum or plasma. It utilizes the chemistry of the Apoenzyme Reactivation Immunoassay System (ARIS) and is designed for use with the Seralyzer reflectance photometer. The 90-s test relies on comparison of strip reactivities with a two-point calibration line, which can be validly stored in the instrument for two weeks. Within-run C...

متن کامل

Results by fluorescent immunoassay for phenytoin compared with those by enzyme immunoassay, liquid chromatography, and discrete analysis (Dupont aca).

We describe the Ames Fluorescent Enzyme Immunoassay procedure for the detection of phenytoin in serum, and compare the results with it with those by enzyme immunoassay(EMIT), "high-pressure" liquid chromatography, and the Dupont aca. Sera from 48 patients who were receiving phenytoin were promptly analyzed in duplicate by EMIT, frozen, then assayed within four weeks by the other three methods. ...

متن کامل

A homogeneous fluorescent immunoassay for human immunoglobulin M.

We describe a homogeneous substrate-labeled fluorescent immunoassay for human IgM. In this competitive-binding method we use a fluorogenic substrate for Escherichia coli beta-galactosidase, N-(6-aminohexyl)-7-beta-galactosyl-coumarin-3-carboxamide, which is covalently coupled to IgM. The fluorescence emission intensity of the labeled IgM at 450 nm (with excitation at 400 nm) is negligible, but ...

متن کامل

Substrate-labeled fluorescent immunoassay for measuring dibekacin concentrations in serum and plasma.

We have developed a homogeneous substrate-labeled fluorescent immunoassay for the measurement of dibekacin concentrations in serum and plasma. The fluorogenic enzyme substrate beta-galactosyl-umbelliferone was covalently attached to tobramycin, an aminoglycoside structurally similar to dibekacin, to prepare a fluorogenic drug reagent (FDR). The FDR is nonfluorescent under assay conditions, but ...

متن کامل

Automated fluorometer/photometer system for homogeneous immunoassays.

A fully automated bench-top clinical analyzer (OPTIMATE TM; Ames/Gilford) performs homogeneous fluorescent immunoassays, colorimetric immunoassays, and determinations of routine blood analytes; drugs, enzymes, metabolites, specific proteins, and hormones in serum. Unique features include a combination fluorescence/absorbance aspirating thermocuvette, a photon-counting fluorometer/photometer, a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 1979