Three-dimensional transcranial color-coded sonography of cerebral aneurysms.

نویسندگان

  • C Klötzsch
  • A Bozzato
  • G Lammers
  • M Mull
  • B Lennartz
  • J Noth
چکیده

BACKGROUND AND PURPOSE The role of 2-dimensional transcranial color-coded sonography (2D-TCCS) as a diagnostic tool in cases of vascular alteration is unquestioned. The skill of the operator, however, may be responsible for some intertrial variability. The clinical value of a new, workstation-based, 3D reconstruction system for TCCS was evaluated in patients with intracranial aneurysms. METHODS Thirty patients with 30 intracranial aneurysms were investigated (8 men, 22 women; mean+/-SD age 54+/-17 years). The TCCS examinations were performed with a 2-MHz probe using the power mode. The 3D system (3D-Echotech, Germany) consisted of an electromagnet, which induced a low-intensity magnetic field near the head of the patient. A magnetic position sensor was attached to the ultrasound probe and transmitted the spatial orientation of the probe to a workstation, which also received the corresponding 2D-images from the video-port of the duplex machine. The echo contrast enhancer D-galactose (Levovist, Schering, Germany) was used in all patients to improve the signal-to-noise ratio. All patients underwent presurgical digital subtraction angiography (DSA) to demonstrate the aneurysm. RESULTS Twenty-nine of 30 angiographically proven intracranial aneurysms (97%) were detected by 3D-TCCS. The aneurysmal diameter estimated by DSA ranged from 3 to 16 mm (mean 7. 2+/-3.6 mm). A comparison of the 3 main diameters of each aneurysm revealed a correlation coefficient of 0.95 between DSA and 3D-TCCS. The 3D determination of the aneurysmal size by 2 experienced sonographers correlated with 0.96. CONCLUSIONS 3D-TCCS is a new, noninvasive method to investigate intracranial aneurysms. The differentiation between artifacts and true changes of the vessel anatomy is much easier in 3D-TCCS than in conventional 2D-TCCS. The new method yields an excellent correlation with the gold standard, DSA. Because the same 3D-TCCS data can be postprocessed by different investigators, it may be possible to improve reproducibility and increase the objectivity of transcranial color-coded duplex sonography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial color-coded duplex sonography in cerebral aneurysms.

BACKGROUND AND PURPOSE Diagnosis and successful therapy before rupture of cerebral aneurysms would be most desirable in view of the high mortality and morbidity rates of aneurysmal subarachnoid hemorrhage. Using transcranial color-coded duplex sonography, we studied radiologically proven cerebral aneurysms to define ultrasonographic criteria and sensitivity for their diagnosis and detection. ...

متن کامل

Diagnosis of a displacement of Guglielmi detachable coils by transcranial color-coded sonography.

n recent years, intracranial aneurysms that cause subarachnoid hemorrhage have been treated by an endovascular approach. The use of endovascular Guglielmi detachable coils (GDCs) has improved the radiologic and neurologic outcome of these patients, reaching results similar to those of craniotomy.1 This technique implies certain risks that are decreasing because of the development of new deliver...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Contrast-enhanced three-dimensional transcranial color-coded sonography of intracranial stenoses.

BACKGROUND AND PURPOSE Intracranial stenoses are associated with a considerable number of strokes each year. The clinical value of a workstation-based three-dimensional (3D) reconstruction system for transcranial color-coded sonography was evaluated in patients with intracranial stenosis or occlusion. METHODS Twenty-six patients (13 men, 13 women; mean age, 57 years +/- 12 [SD]) with 36 intra...

متن کامل

Diagnosis of middle cerebral artery occlusion with transcranial color-coded real-time sonography.

PURPOSE To determine the usefulness of transcranial color-coded real-time sonography in detecting occlusion of the horizontal portion of the middle cerebral artery. METHODS Using transcranial color-coded real-time sonography, we measured the end-diastolic flow velocity with incident angle correction and the side-to-side ratio of the end-diastolic flow velocity (the end-diastolic ratio) in bot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 30 11  شماره 

صفحات  -

تاریخ انتشار 1999