Experience of changing between signal and Bactec 9240 blood culture systems in a children's hospital.

نویسندگان

  • J Gray
  • M Brockwell
  • I Das
چکیده

AIM To compare experience of positive blood cultures in successive years before and after changing from Signal (Unipath) to Bactec 9240 (Becton Dickinson) blood culture systems. METHODS Analysis of data collected prospectively on 7967 Signal and 7062 Bactec blood culture sets. RESULTS Significant growths occurred in 5.7% of Signal and 8.9% of Bactec cultures; 33.0% more significant isolates and 24.0% more episodes of bacteraemia were detected in the second year, following introduction of the Bactec system. Inpatient hospital activity increased by 8.2% between the first and second years, although the numbers of blood cultures received actually fell by 11.4%. There were striking increases in numbers of isolates of coagulase negative staphylococci (47.7%) and Enterobacteriaceae (56.8%) from Bactec cultures. Two anaerobic bacteraemias were detected in Signal blood cultures, whereas none was detected by the Bactec system, despite 12.1% of sets including an anaerobic bottle. Of significant positive cultures, 90.2% were detected within one day with the Bactec 9240, compared with only 50.0% of Signal cultures; 20.7% of significant positive Signal blood cultures were detected only on terminal subculture. Microorganisms that were not significant were isolated from 5.1% Signal and 3.8% Bactec cultures. CONCLUSIONS Compared with the Signal system, the Bactec 9240 offers markedly more rapid and sensitive detection of bacteraemia, together with a lower rate of non-significant isolates. However, using a single PEDS PLUS/F bottle the few episodes of anaerobic bacteraemia that occur in children are likely to be missed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems.

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Str...

متن کامل

Comparison of BACTEC 9240 Peds Plus medium and isolator 1.5 microbial tube for detection of Brucella melitensis from blood cultures.

The sensitivity and time to detection of Brucella melitensis by the BACTEC 9240 and the Isolator blood culture systems were compared in a prospective volume-controlled study. Blood sample aliquots, obtained from children with suspected brucellosis, were inoculated into a BACTEC 9240 Peds Plus bottle and into an Isolator 1.5 Microbial Tube. Overall, 122 pairs of blood samples for culture were ob...

متن کامل

Effect of inoculum size on detection of Candida growth by the BACTEC 9240 automated blood culture system using aerobic and anaerobic media.

Simulated candidemia was produced with 20 Candida isolates at three inoculum sizes (100, 10, and 1 CFU/ml of blood). Growth detection was better with larger inocula. The time to growth detection was shorter with larger inocula. Inoculum size does effect Candida growth detection and time to detection in BACTEC 9240 automated systems.

متن کامل

Comparison of the Bactec 9240 and BacT/Alert blood culture systems for evaluation of placental cord blood for transfusion in neonates.

The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system ...

متن کامل

محیط کشت باکتِک یک روش موثر برای جدا کردن میکروارگانیسم‌ها از نواحی استریل بدن

Background: Infectious diseases are problematic in all around the world especially in the developing countries and early diagnosis of infections and one etiologic agents has a major role in the treatment of one patients. There are some culturing methods consist of conventional, semiautomatic and automatic. One of automatic methods is BACTEC system worked by fluorescent technology and Co2 produc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 1998