Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors.

نویسندگان

  • Philipp Babilas
  • Philipp Lamby
  • Lukas Prantl
  • Stephan Schreml
  • Ernst Michael Jung
  • Gregor Liebsch
  • Otto S Wolfbeis
  • Michael Landthaler
  • Rolf-Markus Szeimies
  • Christoph Abels
چکیده

BACKGROUND Oxygen-dependent quenching of luminescence using transparent planar sensor foils was shown to overcome the limitations of the polarographic electrode technique in an animal model. This method was then transferred to a clinical setting to measure the transcutaneous pO(2) (p(tc)O(2)). METHODS In six healthy subjects, a cuff on the upper arm was occluded up to 20 mmHg above systolic pressure and released after 8 min. P(tc)O(2) was measured at the lower arm every 30 s before, during, and up to 20 min after cuff occlusion (40 degrees C applied skin temperature) using luminescence lifetime imaging (LLI) of platinum(II)-octaethyl-porphyrin immobilized in a polystyrene matrix. For validation, the polarographic Clark electrode technique was applied in close proximity, and measurements were conducted simultaneously. RESULTS P(tc)O(2) measurements before (70.8+/-19.1 vs. 66.2+/-7.7 mmHg) and at the end of ischemic (2.7+/-1.2 vs. 3.6+/-1.7 mmHg) and reperfusion phases (72.2+/-3.6 vs. 68.4+/-8.9 mmHg) did not differ significantly using the Clark electrode vs. LLI. At both the initial ischemic and the reperfusion phases, the Clark electrode measured a faster decrease or increase, respectively, in p(tc)O(2) because of the oxygen consumption occurring in this method. CONCLUSION The presented method provides accurate and reproducible p(tc)O(2) values under changing microcirculatory conditions. The lack of oxygen consumption during measurement allows both a more realistic estimation of p(tc)O(2) than compared with the gold standard and permanent use in regions with critical oxygen supply.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous pO2 measurement during tourniquet-induced venous occlusion using dynamic phosphorescence imaging.

A sufficient oxygen supply in skin grafts requires a functioning microcirculation. Venous occlusion impairs the microcirculation and is therefore a major threat of healing. Luminescence life time imaging (LLI) enables the non-invasive and two-dimensional assessment of the transcutaneous oxygen partial pressure (p(tc)O2). In the current trial this new device was applied for monitoring of venous ...

متن کامل

A defective angina pectoris pain warning system: experimental findings of ischemic and electrical pain test.

Ischemic pain threshold and tolerance levels using the tourniquet pain technique and electrical cutaneous pain thresholds were measured in patients with asymptomatic ischemic heart disease. Thirty asymptomatic patients, who repeatedly exhibited no angina pectoris pain during the occurrence of exercise-induced coronary ischemia (greater than or equal to 0.1 mV ST segment depression in exercise E...

متن کامل

Transcutaneous oxygen monitoring during fiberoptic bronchoscopy.

A transcutaneous oxygen sensor was used to detect the development of hypoxemia in patients undergoing fiberoptic bronchoscopy. Measurements of transcutaneous PO2 (tcPO2) correlated well with arterial PO2 (PaO2), and correctly detected all instances when PaO2 was less than 65 mm Hg. The sensor was noninvasive and caused no adverse effects.

متن کامل

Evaluation of tumor ischemia in response to an indole-based vascular disrupting agent using BLI and (19)F MRI.

Vascular disrupting agents (VDAs) have been proposed as an effective broad spectrum approach to cancer therapy, by inducing ischemia leading to hypoxia and cell death. A novel VDA (OXi8007) was recently reported to show rapid acute selective shutdown of tumor vasculature based on color-Doppler ultrasound. We have now expanded investigations to noninvasively assess perfusion and hypoxiation of o...

متن کامل

First experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors

Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes in pO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2008