Rapid field-cycling MRI using fast spin-echo.

نویسندگان

  • P James Ross
  • Lionel M Broche
  • David J Lurie
چکیده

PURPOSE Fast field-cycling MRI (FFC-MRI) is a technique that promises to expand upon the diagnostic capabilities of conventional MRI by allowing the main field, B0 , to be varied during a pulse sequence, thus allowing access to new types of endogenous contrast. However, this necessitates longer scan times, which can limit the technique's application to clinical research. In this paper, an adaptation of the fast spin-echo (FSE) pulse sequence for use with FFC-MRI is presented, known as field-cycling fast spin-echo (FC-FSE). This technique allows much faster image acquisition, thus shortening scan times significantly. METHODS Image quality and relaxometric accuracy were assessed by comparison of phantom images with data obtained using conventional techniques. As proof of principle, relaxometric images were obtained from the thighs of a human volunteer. RESULTS Image quality remains good for speedup factors of up to 4-fold. The accuracy of relaxometry data is in good agreement with conventional techniques. Results from a volunteer study were encouraging, demonstrating that the technique is sensitive enough to detect quadrupole peaks in vivo. CONCLUSION The technique has been demonstrated in phantom experiments with little loss of image quality or relaxometric accuracy. Initial in-vivo results pave the way for future clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Field-Cycling Relaxometric Imaging using Fast Spin-Echo

The quadrupole peaks arising due to immobile proteins in muscle are clearly visible (see arrows). Figure 1: Dispersion curves for a phantom of crosslinked BSA obtained using the FC-FSE sequence (solid dots) show good agreement with results from a commercial relaxometer (open circles). Rapid Field-Cycling Relaxometric Imaging using Fast Spin-Echo Peter J Ross, Lionel M Broche, Kerrin J Pine, and...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Reliable Cortical Thickness Estimation with Reduction of Susceptibility-Induced Signal Loss using Optimized T1-Weighted Single-Slab 3D Turbo Spin Echo Pulse Sequence

Introduction: In brain volumetry, magnetization-prepared rapid gradient recalled echo (MP-RAGE) imaging [1], which yields a strong T1-weighted contrast among brain tissues and thus a highly accurate segmentation of the brain structures, has been widely used. However, since signals in MPRAGE result from free induction decay (FID) without radio-frequency (RF) pulse induced refocusing, conventiona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 2015