Comparison of Outcomes after Atlantoaxial Fusion with Transarticular Screws and Screw-Rod Constructs

نویسندگان

  • Ji Yong Kim
  • Chang Hyun Oh
  • Seung Hwan Yoon
  • Hyeong-Chun Park
  • Hyun Sung Seo
چکیده

OBJECTIVE The purpose of this study was to compare the radiological and neurological outcomes between two atlantoaxial fusion method for atlantoaxial stabilization; C1 lateral mass-C2 pedicle screws (screw-rod constructs, SRC) versus C1-2 transarticular screws (TAS). METHODS Forty-one patients in whom atlantoaxial instability was treated with atlantoaxial fixation by SRC group (27 patients, from March 2005 to May 2011) or TAS group (14 patients, from May 2000 to December 2005) were retrospectively reviewed. Numeric rating scale (NRS) for pain assessment, Oswestry disability index (ODI), and Frankel grade were also checked for neurological outcome. In radiologic outcome assessment, proper screw position and fusion rate were checked. Perioperative parameters such as blood loss during operation, operation time, and radiation exposure time were also reviewed. RESULTS The improvement of NRS and ODI were not different between both groups significantly. Good to excellent response in Frankel grade is shown similarly in both groups. Proper screw position and fusion rate were also observed similarly between two groups. Total bleeding amount during operation is lesser in SRC group than TAS group, but not significantly (p=0.06). Operation time and X-ray exposure time were shorter in SRC group than in TAS group (all p<0.001). CONCLUSION Both TAS and SRC could be selected as safe and effective treatment options for C1-2 instability. But the perioperative result, which is technical demanding and X-ray exposure might be expected better in SRC group compared to TAS group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques.

STUDY DESIGN Six different techniques for atlantoaxial fixation were biomechanically compared in vitro by nondestructive testing. OBJECTIVE To evaluate the immediate three-dimensional stability of a new atlas claw combined with transarticular screws and alternative techniques for transarticular screw fixation in comparison with established techniques. SUMMARY OF BACKGROUND DATA Posterior tr...

متن کامل

Biomechanical comparison of C1-C2 posterior arthrodesis techniques.

STUDY DESIGN Biomechanical comparison of 5 atlantoaxial posterior arthrodesis techniques. OBJECTIVE To assess the relative value of different posterior wire constructs when one or two transarticular screws are used. SUMMARY OF BACKGROUND DATA A combination of Gallie or Brooks techniques and 2 posterior transarticular screws has been shown to be effective for atlantoaxial arthrodesis. Anatom...

متن کامل

Transarticular screw fixation for atlantoaxial instability - modified Magerl's technique in 38 patients

BACKGROUND Symptomatic atlantoaxial instability needs stabilization of the atlantoaxial joint. Among the various techniques described in literature for the fixation of atlantoaxial joint, Magerl's technique of transarticular screw fixation remains the gold standard. Traditionally this technique combines placement of transarticular screws and posterior wiring construct. The aim of this study is ...

متن کامل

Atlantoaxial transarticular screw fixation for a high-riding vertebral artery.

STUDY DESIGN The feasibility of inserting a screw for the narrow isthmus with a high-riding vertebral artery was evaluated in patients subjected to posterior atlantoaxial transarticular screw fixation. OBJECTIVE To demonstrate the feasibility of inserting bilateral screws and obtaining a stable atlantoaxial complex for patients with a high-riding vertebral artery. SUMMARY OF BACKGROUND DATA...

متن کامل

A novel method of C1–C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block

Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014