A 12-week clinical comparison of an oscillating-rotating power brush versus a marketed sonic brush with self-adjusting technology in reducing plaque and gingivitis.
نویسندگان
چکیده
OBJECTIVE The aim of this investigation was to assess the comparative gingivitis and plaque reduction efficacy of a leading oscillating-rotating power toothbrush and a recently introduced sonic toothbrush in adults with gingivitis. METHODS This was a 12-week, randomized and controlled, parallel group, examiner-blind, single-center clinical study of 130 adults with pre-existing gingivitis and plaque. At baseline, the Modified Gingival Index (MGI), Gingival Bleeding Index (GBI), and total number of bleeding sites were assessed, along with plaque levels (whole mouth, gingival margin, and interproximal) via the Rustogi Modified Navy Plaque Index (RMNPI). Qualified subjects were randomly assigned to one of two power toothbrush test groups: the Oral-B Triumph with SmartGuide (marketed in the United States as the Oral-B Professional Care SmartSeries 5000 [D34]) oscillating-rotating brush, or the Colgate ProClinical A1500 (also marketed as elmex ProClinical) sonic brush. Subjects brushed at home for two minutes twice daily with their assigned power toothbrush and a marketed sodium fluoride dentifrice, and were reevaluated for gingivitis at Week 4 and Week 12 via the MGI, GBI, and total number of bleeding sites, and for plaque reduction via the RMNPI. RESULTS Ninety-seven percent (97%) of the 130 enrolled subjects completed the trial and 62 and 65 subjects in the oscillating-rotating and sonic brush groups, respectively, had evaluable data for analysis. Statistically significant mean reductions in all three gingivitis parameters and plaque relative to baseline were seen at both Weeks 4 and 12 with unsupervised use of both test toothbrushes (p < 0.001). The oscillating-rotating power brush provided statistically significantly superior reductions compared to the sonic brush in mean adjusted MGI (31% and 29% at Weeks 4 and 12, respectively; p < 0.001), GBI (17% at Week 12; p = 0.047), and total number of bleeding sites (48% and 30% at Weeks 4 and 12, respectively; p = 0.002), and produced statistically significantly greater relative mean adjusted plaque reductions for RMNPI whole mouth plaque (38% and 24% at Weeks 4 and 12, respectively; p < 0.001), gingival margin plaque (36% at Week 4; p = 0.004), and interproximal plaque (39% and 26% at Weeks 4 and 12, respectively; p < 0.001). Both power toothbrushes were well-tolerated. CONCLUSION An advanced oscillating-rotating power toothbrush produced substantial, statistically superior reductions in plaque and gingivitis via multiple outcome measures compared to a new sonic toothbrush after both four weeks and 12 weeks of tooth brushing.
منابع مشابه
A randomized clinical trial evaluating gingivitis and plaque reduction of an oscillating-rotating power brush with a new brush head with angled bristles versus a marketed sonic brush with self-adjusting technology.
PURPOSE To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Pro 7000 SmartSeries and Oral-B CrossAction brush head) versus a marketed sonic toothbrush (Colgate ProClinical A1500 with the Triple Clean brush head) in the reduction of gingivitis and plaque over a 6-week period. METHODS This was a single cent...
متن کاملA 4-week clinical comparison of an oscillating-rotating power brush versus a marketed sonic brush in reducing dental plaque.
PURPOSE To assess the plaque removal efficacy of an oscillating-rotating power brush relative to a newly-introduced sonic power brush. METHODS This study used a randomized, examiner-blind, single-center, two-treatment, parallel group 4-week design. Subjects with pre-existing plaque scores of at least 1.75 on the Turesky Modification of the Quigley-Hein Plaque Index (TMQHPI) were evaluated for...
متن کاملAn Eight-Week Clinical Evaluation of an Oscillating-Rotating Power Toothbrush with a Brush Head Utilizing Angled Bristles Compared with a Sonic Toothbrush in the Reduction of Gingivitis and Plaque.
OBJECTIVE To evaluate and compare the efficacy of an oscillating-rotating (O-R) power toothbrush with a brush head utilizing angled bristles to a marketed sonic toothbrush in the reduction of plaque and gingivitis over an eight-week period. METHODS This study used a randomized, examiner-blind, single-center, two-treatment, parallel group, eight-week design. Subjects with mild-to-moderate plaq...
متن کاملA six-week clinical evaluation of the plaque and gingivitis efficacy of an oscillating-rotating power toothbrush with a novel brush head utilizing angled CrissCross bristles versus a sonic toothbrush.
OBJECTIVE To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Triumph with SmartGuide with Oral-B CrossAction brush head) versus a sonic toothbrush (Sonicare DiamondClean) for plaque and gingivitis reduction over a six-week period. METHODS This was a single-center, randomized, examiner-blind, two-treatmen...
متن کاملEvaluation of a new multi-directional power toothbrush versus a marketed sonic toothbrush on plaque and gingivitis efficacy.
PURPOSE To evaluate the plaque- and gingivitis-reducing efficacy of a newly developed multi-directional power toothbrush in comparison to a commercially-available sonic power toothbrush. METHODS Adult subjects with mild-to-moderate gingivitis were eligible for this 4-week, randomized and controlled, single-center, examiner-blinded, parallel group study. At baseline, plaque and gingivitis stat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of clinical dentistry
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2013