Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.

نویسندگان

  • M Doss
  • S Martens
  • J P Wood
  • T Aybek
  • P Kleine
  • G Wimmer Greinecker
  • A Moritz
چکیده

OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were randomized to receive either the stented Perimount (n=20) or the stentless Prima Plus (n=20) bioprosthesis. Left ventricular mass regression, effective orifice area, ejection fraction and mean gradients were evaluated at discharge, 6 months and 1 year after surgery. RESULTS Overall a significant decrease in left ventricular mass was found 1 year postoperatively. However, there was no significant difference in the rate of left ventricular mass regression between the groups. Furthermore, 1 year postoperatively, the hemodynamic performance of the valves and the change in the ejection fraction did not differ between the groups. CONCLUSIONS Our study shows that in a randomized cohort of elderly patients with aortic stenosis, we were not able to detect significant differences, with regard to hemodynamic performance and regression of left ventricular mass, between the stentless and stented valve groups. To our surprise, previously reported findings of non-randomized trials that showed faster and more complete regression of left ventricular mass and hemodynamic benefits of stentless valves were not reproducible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are stentless valves superior to modern stented valves? A prospective randomized trial.

BACKGROUND It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-...

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial.

AIMS We sought to assess the haemodynamic profile of the Freedom stentless aortic valve compared with a stented bioprosthesis in a randomized controlled trial using echocardiography. METHODS AND RESULTS Sixty patients (mean age 73 years) undergoing bioprosthetic aortic valve replacement (AVR) were randomized to either Sorin Freedom stentless (n=31) or Sorin More stented (n=29) valves. The pri...

متن کامل

Stentless aortic valves. Current aspects

The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....

متن کامل

Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses.

OBJECTIVES The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to their hemodynamic behavior during exercise. BACKGROUND Stentless aortic bioprostheses have better hemodynamic performances at rest than stented bioprostheses, but very few comparisons were performed during exercise. METHODS Thirty-eight patients with normally functioning s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2003