Continuous recording of coronary sinus oxygen saturation during atrial pacing in patients with coronary artery disease or with syndrome X.
نویسندگان
چکیده
Coronary sinus oxygen saturation was measured continuously during incremental atrial pacing in 34 patients undergoing cardiac catheterisation. In eleven patients with normal coronary arteriograms, negative exercise tests, and no ST segment depression on the electrocardiogram, an increase in the rate of atrial pacing transiently decreased coronary sinus oxygen saturation but within 20 s oxygen saturation returned to the control value. In six patients with coronary artery disease ST segment depression developed during atrial pacing. The coronary sinus oxygen saturation fell and remained reduced until pacing was discontinued. The size of the fall of coronary sinus oxygen saturation increased with increasing heart rate. In seven patients with coronary artery disease the ST segments were unaltered during atrial pacing and coronary sinus oxygen saturation did not fall. Ten patients with syndrome X were studied. In six ST segment depression developed on atrial pacing. In five, three of whom developed ST segment depression, the changes in coronary sinus oxygen saturation during atrial pacing were similar to those observed in patients without any evidence of coronary artery disease. In three, all of whom developed ST segment depression, coronary sinus oxygen saturation gradually increased throughout the period of atrial pacing. In two patients coronary sinus oxygen saturation fell in a manner similar to that observed in patients with obstructive coronary artery disease who developed ST segment depression on pacing. Thus regulation of coronary blood flow in normal persons in response to an increase of heart rate is rapid. Oxygen extraction across the coronary bed can increase by up to 30% and a persistent increase in oxygen extraction is an indicator of myocardial ischaemia. The term "syndrome X" does not describe a homogeneous group of patients but in the majority coronary sinus oxygen saturation does not fall despite symptoms and changes on the electrocardiogram, indicating that inadequate coronary blood flow is not the dominant mechanism.
منابع مشابه
Continuous coronary sinus and arterial pH monitoring during pacing-induced ischaemia in coronary artery disease.
Catheter tip pH electrodes were used for continuous recording of coronary sinus and arterial pH during atrial pacing in 20 patients undergoing coronary arteriography for chest pain. An ischaemic response to atrial pacing was identified by the onset of angina and/or electrocardiographic abnormalities. Technically satisfactory coronary sinus recordings were obtained in 18 patients. Mean coronary ...
متن کاملCoronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow.
In seven patients thermodilution coronary sinus flow (TD-CSF) was higher (164 +/- 21 ml/min) during ventricular pacing than during atrial pacing (119 +/- 21 ml/min, P less than 0.005) at identical heart rate, without an increase in the determinants of myocardial oxygen consumption. To assess the possibility of right atrial admixture in coronary sinus blood during ventricular pacing we compared ...
متن کاملShort-term effects of right atrial, right ventricular apical, and atrioventricular sequential pacing on myocardial oxygen consumption and cardiac efficiency in patients with coronary artery disease.
OBJECTIVE To investigate the short-term effects of atrial, atrioventricular, and ventricular pacing on myocardial oxygen consumption, myocardial blood flow, and cardiac efficiency in patients with coronary artery disease. DESIGN Prospective study that started at the end of diagnostic coronary angiography in 13 patients and was performed during atrial, atrioventricular, and ventricular pacing ...
متن کاملEffects of pharmacologically-induced hypertension on myocardial ischemia and coronary hemodynamics in patients with fixed coronary obstruction.
Twenty patients with fixed coronary artery obstruction were studied during rapid atrial pacing and methoxamine infusion. During pacing to heart rates of 142 +/- 4 (mean +/- SEM) beats per minute coronary sinus flow increased from 108 +/- 8 to 187 +/- 15 cc/min and myocardial oxygen consumption increased by + 80 +/- 11%. During methoxamine infusion that raised arterial systolic pressure to 196 +...
متن کاملEffects of selective and non-selective beta-adrenergic blockade on coronary dynamics in man assessed by rapid atrial pacing.
The effects on coronary dynamics of propranolol and atenolol were studied in 12 patients undergoing cardiac catheterisation for suspected coronary artery disease. Myocardial blood flow was measured using the coronary sinus continuous thermodilution technique. Data were obtained immediately after drug administration and during rapid atrial pacing. The immediate effects were similar for both drug...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 59 1 شماره
صفحات -
تاریخ انتشار 1988