The influence of patient size on dose conversion coefficients
نویسندگان
چکیده
In this study, the influence of patient size on organ and effective dose conversion coefficients (DCCs) was investigated for a representative interventional fluoroscopic procedure—cardiac catheterization. The study was performed using hybrid phantoms representing an underweight, average and overweight American adult male. Reference body sizes were determined using the NHANES III database and parameterized based on standing height and total body mass. Organ and effective dose conversion coefficients were calculated for anterior–posterior, posterior–anterior, left anterior oblique and right anterior oblique projections using the Monte Carlo code MCNPX 2.5.0 with the metric dose area product being used as the normalization factor. Results show body size to have a clear influence on DCCs which increased noticeably when body size decreased. It was also shown that if patient size is neglected when choosing a DCC, the organ and effective dose will be underestimated to an underweight patient and will be overestimated to an underweight patient, with errors as large as 113% for certain projections. Results were further compared with those published for a KTMAN-2 Korean patient-specific tomographic phantom. The published DCCs aligned best with the hybrid phantom which most closely matched in overall body size. These results highlighted the need for and the advantages of phantom-patient matching, and it is recommended that hybrid phantoms be used to create a more diverse 5 Address for correspondence: Advanced Laboratory for Radiation Dosimetry Studies (ALRADS), Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611-8300, USA. 0031-9155/09/123613+17$30.00 © 2009 Institute of Physics and Engineering in Medicine Printed in the UK 3613 3614 P Johnson et al library of patient-dependent anthropomorphic phantoms for medical dose reconstruction.
منابع مشابه
Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملEffect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملThe influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization.
In this study, the influence of patient size on organ and effective dose conversion coefficients (DCCs) was investigated for a representative interventional fluoroscopic procedure-cardiac catheterization. The study was performed using hybrid phantoms representing an underweight, average and overweight American adult male. Reference body sizes were determined using the NHANES III database and pa...
متن کاملدزیمتری in-vivo در پرتودرمانی خارجی تومورهای مغزی تحت درمان با فوتون MV15 با استفاده از فیلم گاف کرومیک EBT3
Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...
متن کاملSize specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT
Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...