Technical Note, Design and Performance of the GeneChip® Human Genome U133 Plus 2.0 and Human Genome U133A 2.0 Array

ثبت نشده
چکیده

The GeneChip® Human Genome U133 Plus 2.0 (HG-U133 Plus 2.0) and GeneChip Human Genome U133A 2.0 (HG-U133A 2.0) Arrays represent the latest evolution in the Affymetrix® GeneChip Expression Analysis Platform, offering the most comprehensive tool for the analysis of genome-wide expression on a single array. The HG-U133 Plus 2.0 Array includes all of the probe sets from the previous generation HG-U133A and HG-U133B Arrays, as well as nearly 10,000 additional probe sets. The increased feature density of the HG-U133 Plus 2.0 Array offers researchers the ability to measure transcription over the entire human genome in a single hybridization. Greater than 54,000 probe sets are used to analyze the expression level of more than 47,000 transcripts and variants, including approximately 38,500 well-characterized human genes. The HG-U133A 2.0 Array also leverages this high-density design to include the content of the previous HG-U133A Array on a smaller format for more efficient analysis. More than 22,000 probe sets are employed to analyze the expression level of over 18,400 transcripts and variants, including more than 14,500 well-characterized human genes. Extensive testing on both arrays revealed that data from the HG-U133A Array are similar to data generated on the higher density HG-U133 Plus 2.0 and HG-U133A 2.0 Arrays. In terms of assay sensitivity, control spikes were routinely detected in a complex background at a transcript concentration of one copy per 200,000. Technical Note GeneChip Human Genome U133 Plus 2.0

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sequence-based identification of the genes detected by probesets on the Affymetrix U133 plus 2.0 array

One of the biggest problems facing microarray experiments is the difficulty of translating results into other microarray formats or comparing microarray results to other biochemical methods. We believe that this is largely the result of poor gene identification. We re-identified the probesets on the Affymetrix U133 plus 2.0 GeneChip array. This identification was based on the sequence of the pr...

متن کامل

Publications and References for Affymetrix® GeneChip® Exon Arrays

■ Abdueva D., et al. Experimental Comparison and Evaluation of the Affymetrix Exon and U133 Plus 2.0 GeneChip Arrays. PLoS ONE 2(9):e913 (2007). Key Findings: ▪ Abdueva et al. compared the performance of GeneChip Exon Arrays and Human Genome U133 Plus 2.0 Arrays through a series of spike-in hybridization experiments and demonstrated high comparability between the two arrays. ▪ “Despite several ...

متن کامل

Technical Note, Array Design and Performance of the GeneChip® Mouse Expression Set 430

Since the success of an array design is highly dependent on the quality and curation of sequence information, we built tools to address these issues during the design of the GeneChip Human Genome U133 Set (HG-U133).* We then leveraged the knowledge gained from this process and applied a similar method to the GeneChip Mouse Expression Set 430 (Mouse 430) design. The design modifications for the ...

متن کامل

Unexpected presence of mycoplasma probes on human microarrays.

Features The contamination of cell cultures by mycoplasmas poses a problem in that it can adversely affect cellular behavior and physiology; this is exacerbated by the fact that colonization is not easy to detect (1). In a previous study investigating the effects on microarray data, it was shown that mycoplasma contamination can alter patterns of human gene expression by upsetting host cell phy...

متن کامل

Imputing gene expression to maximize platform compatibility

Microarray measurements of gene expression constitute a large fraction of publicly shared biological data, and are available in the Gene Expression Omnibus (GEO). Many studies use GEO data to shape hypotheses and improve statistical power. Within GEO, the Affymetrix HG-U133A and HG-U133 Plus 2.0 are the two most commonly used microarray platforms for human samples; the HG-U133 Plus 2.0 platform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003