Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments.

نویسندگان

  • Rainer Gradaus
  • Klara Mathies
  • Günter Breithardt
  • Dirk Böcker
چکیده

BACKGROUND Foreshortening is a recognized problem that is present in angiography and results from views that are not perpendicular to coronary lesions. This limits visual coronary analysis as well as 2D quantitative coronary angiography systems (QCA). The CardiOp-B System is a 3D image acquisition and processing software system designed as an add-on to conventional X-ray angiography system. CardiOp-B's features include real time and off line analysis with comprehensive 3D reconstruction integrating all of the available information of two 2D vessel angiographies into one 3D image. It was the aim of the study to analyze the accuracy of this new 3D QCA system. METHODS 3D QCA was performed in 50 patients (age 64 +/- 10.9; 84% male; LV-EF 63 +/- 16%) measuring 61 stents during high-pressure inflation (diameter: 2.25-4 mm; length: 8-32 mm). The obtained values (proximal and distal stent diameter, stent length) were correlated with the predefined size of the stents at the used inflation pressure. RESULTS The linear correlation for the proximal stent diameter was Stent(prox)= 0.03 + 0.93 x real stent size (r(2) = 0.85). The linear correlation for the distal stent diameter was Stent(distal)= -0.03 + 0.89 x real stent size (r(2) = 0.81). The linear correlation for the stent length was Stent(length)= -0.61 + 1.02 x real stent length (r(2) = 0.98). CONCLUSIONS The CardiOp-B System(R) is a new 3D QCA system with a high linear correlation between the real vessel size and the obtained vessel dimension. It provides real time or off line accurate and comprehensive diagnostic information to the interventional cardiologist without changing the basic coronary angiography procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary magnetic resonance imaging after routine implantation of bioresorbable vascular scaffolds allows non-invasive evaluation of vascular patency

BACKGROUND Evaluation of recurrent angina after percutaneous coronary interventions is challenging. Since bioresorbable vascular scaffolds (BVS) cause no artefacts in magnetic resonance imaging (MRI) due to their polylactate-based backbone, evaluation of vascular patency by MRI might allow for non-invasive assessment and triage of patients with suspected BVS failure. METHODS Patients with pol...

متن کامل

Comparison of assessment of native coronary arteries by standard versus three-dimensional coronary angiography.

Vessel foreshortening is a major limitation of standard coronary angiography due to the 2-dimensional representation of 3-dimensional structures. Three-dimensional models may overcome it. The aim of this study was to compare measurements of coronary segments from quantitative coronary angiography (QCA) in an operator-selected "working view" of standard 2-dimensional coronary angiography with th...

متن کامل

Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent.

BACKGROUND Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS Fi...

متن کامل

Exercise-induced coronary artery vasodilation is not impaired by stent placement.

BACKGROUND Stenting has proved beneficial for treating threatened closure and reducing restenosis after balloon angioplasty. However, the implantation of a coronary metallic prosthesis has been related to impaired vasomotion distal to the stent as assessed by acetylcholine infusion. Thus, the purpose of the present study was to determine the vasomotion of stented coronary arteries and to assess...

متن کامل

Clinical Implications of Congenital Absence of Circumflex Coronary Artery

Introduction: Coronary artery anomalies are rare clinical entities reported in 0.6% to 5.6% of diagnostic coronary angiographies. Anomalous origins of coronary arteries from distal segments are rarely reported. Presented herein is a coronary anomaly in which the circumflex artery (CX) originated as a continuation of the posterolateral branch of the right coronary artery (RCA) w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 2006