Does chlorhexidine in different formulations interfere with the force of orthodontic elastics?

نویسندگان

  • Matheus Melo Pithon
  • Dandara Andrade Santana
  • Kássio Henrique Sousa
  • Isa Mara Andrade Oliveira Farias
چکیده

OBJECTIVE To evaluate the effects of different concentrations of chlorhexidine on the decline in force of orthodontic elastics. MATERIALS AND METHODS In a laboratory study, five groups of samples were tested, with one control group represented by distilled water (group 1) and four experimental groups: 0.12% manipulated chlorhexidine (group 2), 0.2% manipulated chlorhexidine (group 3), 0.12% chlorhexidine gluconate-based oral solution (0.12% Periogard; group 4), and 0.2% Cleanform mouthwash (formula and action; group 5). The test groups were submersed in artificial saliva at 37°C. Templates were used and submerged in the chlorhexidine solutions for 30 seconds twice a day. Force was measured with a digital dynamometer at six different time intervals: 0, 1, 7, 14, 21, and 28 days. RESULTS No statistical differences were found among the groups in the initial period, at 24 hours, and at 7 days (P > .05). There were statistical differences between groups 2 and 5 at 14 days of the experiment and between group 1 and the others at 28 days. In the initial period, the force was statistically higher than it was at any of the other periods of the experiment (P < .05). CONCLUSION In the present study, chlorhexidine showed no significant influence on the force degradation of the chain elastics tested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elasticity in Elastics-An in-vitro study.

BACKGROUND Orthodontic tooth movement results from application of forces to teeth. Elastics in orthodontics have been used both intra-orally and extra- orally to a great effect. Their use, combined with good patient co-operation provides the clinician with the ability to correct both anteroposterior and vertical discrepancies. Force decay over a period of time is a major problem in the clinical...

متن کامل

Force Relaxation Characteristics of Medium Force Orthodontic Latex Elastics: A Pilot Study

To evaluate force extension relaxation of different brands and diameters of latex elastics subjected to static tensile testing under an apparatus designed to simulate oral environments, sample sizes of 5 elastics from American Orthodontics (AO), Tp, and Morelli Orthodontics (Mo) of equivalent medium force, (3/16, 1/4, and 5/16 inch size) were tested. The forces were read after 1-, 3-, 6-, 12- a...

متن کامل

Effect of Pretreatment with Fluoride, Chlorhexidine, and Mixed Fluoride-Chlorhexidine Gels on Shear Bond Strength of Orthodontic Brackets: An Ex-Vivo Study

Background and Aim: Orthodontic patients are at an increased risk of caries due to difficulty in plaque control. Antimicrobial agents, such as fluoride and chlorhexidine, can be useful in preventing tooth demineralization. The present study aimed to determine the effect of fluoride and chlorhexidine gels and their mixture on the shear bond strength (SBS) of orthodontic brackets. Materials and ...

متن کامل

Latex and non-latex orthodontic elastic force loss due to cyclic temperature.

UNLABELLED The purpose of this study was to compare the force loss of 1/4 inch (6.35mm) 3.5oz (99g) medium latex elastics from Ormco Corp. to non-latex elastics from ClassOne Orthodontics and Phoenix after being cycled between different temperatures. Elastics were stretched to 1.57 inches (40mm) on jigs and cycled in water baths for 4 minutes at 5 degrees C and 37 degrees C, 21 degrees C and 37...

متن کامل

The prestretching effect on the force decay of orthodontic elastic chain.

This in vitro study evaluated the Influence of prestretching, in the force decay of orthodontic elastic chains, at three time intervals: 2, 7 and 30 days with the brands Morelli, Orthometric and American Orthodontics. In the experimental group, prestretching was performed, stretching the elastics to increase them by 50% of their original length three times in a quick and sequential mode. All of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Angle orthodontist

دوره 83 2  شماره 

صفحات  -

تاریخ انتشار 2013