Heart Rate Monitor and Electrocardiograph Fundamentals
نویسنده
چکیده
This application note demonstrates fundamental implementations of the cost effective heart hate monitor (HRM) and electrocardiograph (ECG or EKG) devices using Freescale products. The heart rate monitor is implemented on a low cost MC9RS08KA2 ultra low-end 8-bit microcontroller using an analog comparator module (ACMP) and standard IO pins. The electrocardiograph is implemented on the MC9S08JM60 USB device 8-bit microcontroller using an analog-to-digital converter (ADC) and USB connectivity to send data to a PC.
منابع مشابه
A 14 A ECG Processor with Robust Heart Rate Monitor for a Wearable Healthcare System
This report describes an electrocardiograph (ECG) processor for use with a wearable healthcare system. It comprises an analog front end, a 12-bit ADC, a robust Instantaneous Heart Rate (IHR) monitor, a 32-bit Cortex-M0 core, and 64 Kbyte Ferroelectric Random Access Memory (FeRAM). The IHR monitor uses a short-term autocorrelation (STAC) algorithm to improve the heart-rate detection accuracy des...
متن کاملA 14µA ECG processor with noise tolerant heart rate extractor and FeRAM for wearable healthcare systems
This report describes an electrocardiograph (ECG) processor for use with a wearable healthcare system. It comprises an analog front end, a 12-bit ADC, a robust Instantaneous Heart Rate (IHR) monitor, a 32-bit Cortex-M0 core, and 64 Kbyte Ferroelectric Random Access Memory (FeRAM). The IHR monitor uses a short-term autocorrelation (STAC) algorithm to improve the heart-rate detection accuracy des...
متن کاملHEART RATE: A PREDICTOR OF EARLY MORTALITY IN PATIENTS WITH MYOCARDIAL INFARCTION
A number of epidemiologic studies have reported a positive relationship between heart rate, cardiovascular disease and mortality. To examine the correlation between heart rate and mortality after acute myocardial infarction (AMI), 2147 patients hospitalized in coronary care units in Isfahan were investigated in a cross-sectional study. Their heart rate was measured according to an electroca...
متن کاملValidity of the ithlete™ Smart Phone Application for Determining Ultra-Short-Term Heart Rate Variability
The purpose of this investigation was to cross-validate the ithlete™ heart rate variability smart phone application with an electrocardiograph for determining ultra-short-term root mean square of successive R-R intervals. The root mean square of successive R-R intervals was simultaneously determined via electrocardiograph and ithlete™ at rest in twenty five healthy participants. There were no s...
متن کاملReproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices
Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute wal...
متن کامل