Wakefields excited in the small aperture collimators may damage the beam. As pointed out by K. Bane and P. Morton the wakefields can be reduced considerably by tapering the steps and using the “step+taper” collimator geometry. The optimisation of this kind of geometry for TTF 2 collimators with different apertures is carried out in the paper. For the optimal geometries the nonlinear near-wall wakefields are calculated. The numerical results are confirmed by comparison with analytical estimations for the fully tapered collimator in inductive regime.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collimator Wakefield Calculations for ILC-TRC Report

We summarize the formalism of collimator wakefields and their effect on beams that are near the center of the collimator gap, and apply the formalism to the TESLA, NLC, and CLIC collimation systems. Collimator Wakefield Calculations for ILC-TRC Report

متن کامل

Measurements of Collimator Wakefields at End Station A*

The angular deflection of a 28.5 GeV electron beam passing off-axis between the jaws of a collimator, generating a transverse wakefield, were measured in End Station A (ESA) at SLAC. In total, fifteen different configurations of collimator geometry and material were tested: some were chosen for compatibility with previous measurements while others served to study the effect of geometry and tape...

متن کامل

Numerical Calculations of Short-range Wakefields of Collimators

The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...

متن کامل

Transverse Wakefields from Tapered Collimators: Measurements and Analysis

We report on a series of measurements of the transverse wakefield from tapered collimators. The collimators were designed to principally present a geometric impedance to the beam, and to minimize impedances from resistivity or surface features; in addition, the geometries of the collimators were selected to permit examination of the scaling behavior of the wakefield due to collimator taper angl...

متن کامل

Wakefield Induced Correlated Energy Spread and Emittance Growth at TTF FEL

An electron beam with a small energy spread (0.1%) and a small normalized emittance (2 mm.mrad) is required to drive a Free Electron Laser at the TESLA Test Facility (TTF) at DESY. During FEL operations, the longitudinal and transverse wakefields which are generated by vacuum components, principally by RF cavities, bellows and valves, will induce an additional energy spread and emittance growth...