Alternans and 2:1 rhythms in an ionic model of heart cells.

نویسندگان

  • Christian Zemlin
  • Eberhard Storch
  • Hanspeter Herzel
چکیده

ECG alternans is commonly held to be an indicator of electrical instability of the heart, but the development of alternans has not yet been fully understood theoretically. We investigate the onset of alternans and 2:1 rhythms for stimulation at increasing frequencies in the Beeler-Reuter model, a simple ionic model of cardiac tissue. We find hysteresis and bistability at the onset of alternans; well-timed stimuli can switch between the two limit cycles. We determine quantitatively the effect of blocking specific ionic currents. Moreover, we find that calcium buffers generally promote alternans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rhythms of high-grade block in an ionic model of a strand of regionally ischemic ventricular muscle.

Electrical alternans, a beat-to-beat alternation in the electrocardiogram or electrogram, is frequently seen during the first few minutes of acute myocardial ischemia, and is often immediately followed by malignant cardiac arrhythmias such as ventricular tachycardia and ventricular fibrillation. As ischemia progresses, higher-order periodic rhythms (e.g., period-4) can replace the period-2 alte...

متن کامل

Triggered alternans in an ionic model of ischemic cardiac ventricular muscle.

It has been known for several decades that electrical alternans occurs during myocardial ischemia in both clinical and experimental work. There are a few reports showing that this alternans can be triggered into existence by a premature ventricular contraction. Detriggering of alternans by a premature ventricular contraction, as well as pause-induced triggering and detriggering, have also been ...

متن کامل

Ionic mechanism of electrical alternans.

Although alternans of action potential duration (APD) is a robust feature of the rapidly paced canine ventricle, currently available ionic models of cardiac myocytes do not recreate this phenomenon. To address this problem, we developed a new ionic model using formulations of currents based on previous models and recent experimental data. Compared with existing models, the inward rectifier K(+)...

متن کامل

Hysteresis and bistability in the direct transition from 1:1 to 2:1 rhythm in periodically driven single ventricular cells.

The transmembrane potential of a single quiescent cell isolated from rabbit ventricular muscle was recorded using a suction electrode in whole-cell recording mode. The cell was then driven with a periodic train of current pulses injected into the cell through the same recording electrode. When the interpulse interval or basic cycle length (BCL) was sufficiently long, 1:1 rhythm resulted, with e...

متن کامل

Alternans and higher-order rhythms in an ionic model of a sheet of ischemic ventricular muscle.

Life-threatening arrhythmias such as ventricular tachycardia and fibrillation often occur during acute myocardial ischemia. During the first few minutes following coronary occlusion, there is a gradual rise in the extracellular concentration of potassium ions ([K(+)](0)) within ischemic tissue. This elevation of [K(+)](0) is one of the main causes of the electrophysiological changes produced by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio Systems

دوره 66 1-2  شماره 

صفحات  -