Novel Modeling and Control Strategies for a HVAC System Including Carbon Dioxide Control

نویسندگان

  • Chang-Soon Kang
  • Jong-Il Park
  • Mignon Park
  • Jaeho Baek
چکیده

Conventional heating, ventilating, and air conditioning (HVAC) systems have traditionally used the temperature and the humidity ratio as the quantitative indices of comfort in a room. Recently, the carbon dioxide (CO2) concentration has also been recognized as having an important contribution to room comfort. This paper presents the modeling of an augmented HVAC system including CO2 concentration, and its control strategies. Because the proposed augmented HVAC system is multi-input multi-output (MIMO) and has no relative degree problem, the dynamic extension algorithm can be employed; then, a feedback linearization technique is applied. A linear-quadratic regulator (LQR) is designed to optimize control performance and to stabilize the proposed HVAC system. Simulation results are provided to validate the proposed system model, as well as its linearized control system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

Fuzzy Control of Carbon Dioxide Concentration in Premises

The carbon dioxide concentration in rooms with varying number of people is an important safety and comfort factor. Its control via ventilation is accompanied by two drawbacks the increased energy consumption and dependence on the quality of the fresh air used. Fuzzy logic can ensure energy efficient control of the carbon dioxide concentration. The aim of the present research is to develop a des...

متن کامل

Energy Efficient Fuzzy Logic Control of Indoor Air-Conditioning in Real Time

The indoor human comfort, working efficiency and health are dependent on the control of the quality of air in a heating-ventilation and air-conditioning (HVAC) system. The aim of present paper is to improve this control considering the most important variables – the air temperature, relative humidity and concentration of carbon dioxide by applying fuzzy logic and genetic algorithms (GAs) for co...

متن کامل

Model Predictive Control of HVAC Systems: Design and Implementation on a Real Case Study Laureando

Recently, one of the most debated subjects regards energy savings. Since the percentage of the energy consumptions accounted for buildings is surprisingly higher than the one for the industries and transportations, the society is becoming more and more aware of the importance of the quality of building management. This gives an impulse to the automatic control community to design intelligent co...

متن کامل

Experimental, Kinetics and Isotherm Modeling of Carbon Dioxide Adsorption with 13X Zeolite in a fixed bed column

In this work, zeolite 13X with porosity structure has been used as an adsorbent for adsorption of CO2 flue gas. The effect of operating conditions including pressure and time on adsorption capacity were investigated. The experiments conditions are constant temperature, the range of pressure 1 - 9 bar and the registration of adsorption capacity with passing of time. Experimental data were adjust...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014