Dynamic Impedance Model of the Skin-Electrode Interface for Transcutaneous Electrical Stimulation
نویسندگان
چکیده
Transcutaneous electrical stimulation can depolarize nerve or muscle cells applying impulses through electrodes attached on the skin. For these applications, the electrode-skin impedance is an important factor which influences effectiveness. Various models describe the interface using constant or current-depending resistive-capacitive equivalent circuit. Here, we develop a dynamic impedance model valid for a wide range stimulation intensities. The model considers electroporation and charge-dependent effects to describe the impedance variation, which allows to describe high-charge pulses. The parameters were adjusted based on rectangular, biphasic stimulation pulses generated by a stimulator, providing optionally current or voltage-controlled impulses, and applied through electrodes of different sizes. Both control methods deliver a different electrical field to the tissue, which is constant throughout the impulse duration for current-controlled mode or have a very current peak for voltage-controlled. The results show a predominant dependence in the current intensity in the case of both stimulation techniques that allows to keep a simple model. A verification simulation using the proposed dynamic model shows coefficient of determination of around 0.99 in both stimulation types. The presented method for fitting electrode-skin impedance can be simple extended to other stimulation waveforms and electrode configuration. Therefore, it can be embedded in optimization algorithms for designing electrical stimulation applications even for pulses with high charges and high current spikes.
منابع مشابه
Conductive differences in electrodes used with transcutaneous electrical nerve stimulation devices.
The purpose of this study was to document conductive differences among commercially available electrodes used with transcutaneous electrical nerve stimulation (TENS) devices. Impedance within a model system involving a human subject was calculated from oscilloscopic tracings of the pulse waveform for each of 25 different electrode types. Impedance values ranged from 1,000 to 7,800 omega Possibl...
متن کاملA New Method for Non-Invasive Measurement of Skin in the Low Frequency Range
OBJECTIVES The purpose of our study was to estimate skin structure and conductivity distribution in a cross section of local tissue using non-invasive measurement of impedance data. The present study was designed to evaluate the efficiency of skin depth information through computer simulations. The multilayer tissue model was composed of epidermis, dermis tissues, and subcutaneous. METHODS In...
متن کاملCorrection: Dynamic Impedance Model of the Skin-Electrode Interface for Transcutaneous Electrical Stimulation
A funder is missing from the manuscript’s Funding section. The correct funding statement is as follows: JLVL was supported by the Mexican Council of Research and Technology (CONACYT) grant: 236850 (www.conacyt.mx). This work was also supported by the Vienna Science and Technology Fund (WWTF), Proj.Nr. LS11-057 (www.wwtf.at), and the Wings for Life Spinal Cord Research Foundation (WfL), Proj.Nr....
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملFactors influencing quadriceps femoris muscle torque using transcutaneous neuromuscular electrical stimulation.
Quadriceps femoris muscle torque was measured in 40 subjects during transcutaneous neuromuscular electrical stimulation (NMES). Three different electrode types (carbonized rubber, sponge, and adhesive) were used on each subject, permitting determination of the factors that influenced the magnitude of quadriceps femoris muscle torque induced by NMES. This goal was accomplished by entering the va...
متن کامل