Atlas of the Spectrum of a Platinum/Neon Hollow-Cathode Reference Lamp in the Region 1130–4330 Å
نویسندگان
چکیده
The spectrum of a platinum hollow-cathode lamp containing neon carrier gas was recorded photographically and photoelectrically with a 10.7 m normal-incidence vacuum spectrograph. Wavelengths and intensities were determined for about 5600 lines in the region 1130-4330 Å. An atlas of the spectrum is given, with the spectral lines marked and their intensities, wavelengths, and classifications listed. Lines of impurity species are also identified. The uncertainty of the photographically measured wavelengths is estimated to be ± 0.0020 Å. The uncertainty of lines measured in the photoelectric scans is 0.01 Å for wavelengths shorter than 2030 Å and 0.02 Å for longer wavelengths. Ritz-type wavelengths are given for many of the classified lines of Pt II with uncertainties varying from ±0.0004 to ± 0.0025 Å. The uncertainty of the relative intensities is estimated to be about 20%.
منابع مشابه
TWO PHOTON TRANSITIONS IN THE OPTOGALVANIC SPECTRUM OF NEON
Seventeen two-photon transitions for neon have been observed in the 580- 635 nm spectral region for use in the spectroscopic study of its higher excited levels, which are not accessible by one-photon absorption. To compare the two and one-photon absorption signals originating from the same lower level, an effort was made to record single-photon optogalvanic spectrum in the available wavele...
متن کاملHollow Cathode Discharges for Gas Lasers
With the exception of the 632.8 nm neon line all the important visible and ultraviolet cw gas laser lines belong to the spectra of ionized atoms. To achieve proper laser oscillation the excitation of the upper levels of these lines is of primary importance. High energy electrons are needed for this process. As such electrons are in high concentration in the hollow cathode discharge, it was obvi...
متن کاملHigh-Resolution Observations of the Infrared Spectrum of Neutral Neon
We have observed the spectrum of neutral neon (Ne I) emitted by a microwave-excited electrodeless discharge lamp with the National Institute of Standards and Technology 2 m Fourier transform spectrometer. The spectra cover the regions 6929 Å to 11 000 Å with a resolution of 0.01 cm(-1) and 11 000 Å to 47 589 Å with a resolution of 0.007 cm(-1). We present a line list that includes more than 650...
متن کاملA new list of thorium and argon spectral lines in the visible ⋆ , ⋆ ⋆
Aims. We present a new list of thorium and argon emission lines in the visible obtained by analyzing high-resolution (R = 110, 000) spectra of a ThAr hollow cathode lamp. The aim of this new line list is to allow significant improvements in the quality of wavelength calibration for medium-to high-resolution astronomical spectrographs. Methods. We use a series of ThAr lamp exposures obtained wit...
متن کاملNone-platinum electrode catalysts and membranes for highly efficient and inexpensive H2 production in microbial electrolysis cells (MECs): A review
Microbial electrolysis cell (MEC) is a gripping bio-electrochemical device producing H2 gas from renewable biomass while at the same time treat wastewater. Through extensive global research efforts in the latest decade, the performance of MECs, including energy efficiency, hydrogen production rate (HPR), and hydrogen recovery have achieved significant breakthroughs. However, employi...
متن کامل